首页> 外文期刊>Food and bioprocess technology >Improved method for mastitis detection and evaluation of disinfectant efficiency during milking process. (CIGR Symposium Special Issue.)
【24h】

Improved method for mastitis detection and evaluation of disinfectant efficiency during milking process. (CIGR Symposium Special Issue.)

机译:在挤奶过程中用于乳腺炎检测和评估消毒效率的改进方法。 (CIGR专题讨论会特刊。)

获取原文
获取原文并翻译 | 示例
           

摘要

In automatic milking systems, rapid methods to detect mastitis and also to prevent mastitis are very important since reduced milk quality and economic losses are the consequences of mastitis. Based on IDF Standard 148 a rapid and reliable method to detect somatic cell count with Coulter Counter technique was developed in this study and the efficiency of peracetic acid (PAA) to prevent bacterial cross-contamination was investigated using Escherichia coli as test microorganism. Besides conventional microbiological methods, flow cytometric analysis using carboxyfluorescein diacetate, thiazole orange, propidium iodide and DiOC2(3) were applied using E. coli as test organism to study the efficiency of PAA. Acceleration of mastitis detection method was realised using centrifugation for lipid separation of foremilk samples before Coulter Counter measurements. During inflammation, an increase in somatic cell count was detected by Coulter Counter with a peak at particle sizes between 8 and 12 micro m. E. coli was reduced by 5.6 log cycles, 7.7 log cycles and 4.9 log cycles after 0.25% PAA treatment for 15 s at 0 degrees C, 10 degrees C and 20 degrees C. However, flow cytometric analysis showed that most of the cells are damaged but still have metabolic activity. The efficiency of PAA against mastitis-related bacteria was shown with plate count methods but flow cytometric analysis indicates that the cells may still have the potential to cause mastitis. The potential of Coulter Counter to detect somatic cell count within a short time was shown in this study. Important data regarding safety monitoring and quality control can be derived with this method.
机译:在自动挤奶系统中,快速检测乳腺炎和预防乳腺炎的方法非常重要,因为降低牛奶质量和经济损失是乳腺炎的后果。本研究基于IDF标准148,开发了一种快速,可靠的库尔特计数器技术来检测体细胞计数的方法,并研究了使用大肠埃希氏大肠杆菌(Escherichia coli)来检测过氧乙酸(PAA)防止细菌交叉污染的效率。 >作为测试微生物。除了常规的微生物学方法外,还使用 E进行了使用羧乙酸双乙酸酯,噻唑橙,碘化丙啶和DiOC 2 (3)的流式细胞仪分析。大肠杆菌作为测试生物,以研究PAA的效率。在离心库尔特计数器之前,通过离心分离前体样本中的脂质来实现乳腺炎检测方法的加速。在发炎期间,通过库尔特计数器检测到体细胞计数增加,并且在8至12微米的粒径处出现一个峰值。 E。在0°C,10°C和20°C下0.25%PAA处理15 s后,大肠杆菌减少了5.6个对数周期,7.7个对数周期和4.9个对数周期。但是,流式细胞仪分析表明,大多数细胞受损但仍具有代谢活性。用平板计数法显示了PAA对抗乳腺炎相关细菌的效率,但流式细胞仪分析表明该细胞可能仍具有引起乳腺炎的潜力。这项研究显示了库尔特计数器在短时间内检测体细胞计数的潜力。使用此方法可以得出有关安全监控和质量控制的重要数据。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号