Quaternary ammonium compound (QAC) residues can increase with each application and build up over a period of time during sanitation of food plants. Therefore, it is crucial to establish a simple but accurate method for routine measurement of QAC residues in food plants. In this study, a spectrophotometric method was validated and applied for the quantification of QAC residues on stainless steel surfaces. This method was based on the formation of a colored ion pair between the quaternary ions and Eosin-Y in the presence of Triton X-100. QAC residues were recovered from surfaces using swabs and were subsequently sonicated, and the isolated extracts were analyzed with a spectrophotometer (535 nm). The method was shown to be selective in the presence of interfering substances, and a linear relationship between the absorbance and concentration of QACs was detected in the concentration range from 0.5 to 10 mg L-1 (r 2
机译:每次应用时,季铵化合物(QAC)残留量都会增加,并在食用植物卫生期间的一段时间内积累。因此,至关重要的是建立一种简单而准确的方法来对食用植物中的QAC残留进行常规检测。在这项研究中,验证了一种分光光度法,并将其用于量化不锈钢表面上的QAC残留量。该方法基于在Triton X-100存在下在四价离子和曙红Y之间形成有色离子对的方法。使用拭子从表面回收QAC残留物,然后进行超声处理,并使用分光光度计(535 nm)对分离的提取物进行分析。结果表明,该方法在存在干扰物质的情况下具有选择性,并且在浓度范围为0.5至10 mg L -1 (r 2 。该方法获得了令人满意的准确度(93-97%)和精确度(相对标准偏差(RSD)<2.7%)。评估擦拭方案对方法的回收率,可重复性和中间精度的影响,结果表明残留物的平均回收率为90%。此外,就重复性和中等精度而言,RSD百分比分别小于8.8%和9.4%。发现QAC残留物在沉积后至少在不锈钢表面上稳定6天,这种处理可能存在潜在风险,尤其是在干洗过程中。版权所有Springer Science + Business Media纽约,2012年。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号