Commercial kits to determine RNA concentrations are expensive, and sometimes too expensive for laboratories working with tight budgets, especially those in developing countries. We developed, tested, and evaluated two home-made two-step reverse transcription-quantitative polymerase chain reaction assays aimed to detect rotavirus in surface water samples. A commercial one-step master kit was used for comparison. Our results indicated that the efficiency of the home-made assays was comparable to the commercial kit. Furthermore, the lowest detection limit of all assays corresponded to 10-0.2 TCID50 (50 % tissue Culture Infective Dose) per ml. The home-made assays were able to detect rotavirus concentrations in complex surface waters in a slum area in Kampala (Uganda) and their performance was comparable to the commercial kit. The total costs of the two home-made assays was 11 times less than the selected commercial kit. Although preparing home-made assays is more time consuming, the assays can be useful for cases in which consumable costs are more important than personnel costs.
机译:用于确定RNA浓度的商业试剂盒价格昂贵,有时对于预算紧张的实验室(尤其是发展中国家的实验室)而言过于昂贵。我们开发,测试和评估了两个自制的两步反转录定量聚合酶链反应测定法,旨在检测地表水样品中的轮状病毒。使用商业的一步式主套件进行比较。我们的结果表明,自制测定的效率与市售试剂盒相当。此外,所有测定的最低检测限对应于每毫升10-0.2 TCID50(50%组织培养物感染剂量)。自制的测定能够检测到坎帕拉(乌干达)贫民区的复杂地表水中轮状病毒的浓度,其性能与市售试剂盒相当。两种自制测定的总成本比所选商业试剂盒低11倍。尽管准备自制化验会比较耗时,但对于耗材成本比人事成本更为重要的情况,化验可能有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号