首页> 外文期刊>Fertility and Sterility: Official Journal of the American Fertility Society, Pacific Coast Fertility Society, and the Canadian Fertility and Andrology Society >Reliability of automated volumetric measurement of multiple growing follicles in controlled ovarian hyperstimulation.
【24h】

Reliability of automated volumetric measurement of multiple growing follicles in controlled ovarian hyperstimulation.

机译:在受控的卵巢过度刺激中对多个生长的卵泡进行自动体积测量的可靠性。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: To evaluate the reliability of a computer-assisted approach for automatically measuring ovarian follicles during controlled ovarian hyperstimulation (COH). DESIGN: Prospective, comparative study. SETTING: Hospital Beclere, Clamart, France. PATIENT(S): Twenty-seven infertile IVF-ET candidates undergoing COH. INTERVENTION(S): Just before the oocyte retrieval, growing follicles (n=72) had their mean diameters measured and their volumes determined semimanually by virtual organ computer-aided analysis (VOCAL) and automatically by SonoAVC. Follicles were sorted in small (12-16 mm; n=35) and large (>16 mm; n=37) growing follicles. Measures were compared with the follicular fluid volume. MAIN OUTCOME MEASURE(S): Concordance of results using intraclass correlation coefficient and limits of agreement methods, respectively. RESULT(S): Overall, VOCAL (median: 3.42 mL; range: 0.98-9.68 mL) and SonoAVC (3.25 mL; 0.98-8.63 mL) measurements were equivalent to the corresponding actual follicle volume (3.20 mL; 0.80-10.20 mL). The intraclass correlation coefficient values between follicular fluid volume and mean diameter, VOCAL, and SonoAVC were 0.51, 0.95, and 0.98, respectively, for small follicles, and 0.80, 0.93, and 0.92, respectively, for large follicles. 95% limits of agreement between actual volume and VOCAL (-1.09 to +1.07 mL) and SonoAVC (-1.08 to +0.84 mL) measurements were comparable in both groups. CONCLUSION(S): Automated measurement of multiple follicular volumes using SonoAVC is a simple technique, which reliability is superior to usual diameter measurements and comparable to VOCAL. This technologic refinement invites us to switch toward volumetric monitoring of follicle growth during COH.
机译:目的:评估可控制的卵巢过度刺激(COH)期间自动测量卵巢卵泡的计算机辅助方法的可靠性。设计:前瞻性比较研究。地点:法国克拉玛特,贝克莱尔医院。患者:接受COH的27名不育IVF-ET候选人。干预:在取卵之前,通过虚拟器官计算机辅助分析(VOCAL)手动测量生长的卵泡(n = 72)的平均直径,并通过SonoAVC自动确定其体积。将卵泡分为生长中的小卵泡(12-16 mm; n = 35)和大(> 16 mm; n = 37)。将测量值与卵泡液量进行比较。主要观察指标:使用类内相关系数和一致度限制的结果一致。结果:总体而言,VOCAL(中位数:3.42 mL;范围:0.98-9.68 mL)和SonoAVC(3.25 mL; 0.98-8.63 mL)测量值相当于相应的实际卵泡体积(3.20 mL; 0.80-10.20 mL) 。小卵泡的卵泡液体积与平均直径,VOCAL和SonoAVC之间的类内相关系数值分别为0.51、0.95和0.98,大卵泡分别为0.80、0.93和0.92。两组的实际体积和VOCAL(-1.09至+1.07 mL)和SonoAVC(-1.08至+0.84 mL)测量值之间的一致性95%在两组中相当。结论:使用SonoAVC自动测量多个卵泡体积是一种简单的技术,其可靠性优于常规直径测量,可与VOCAL媲美。这种技术上的改进使我们转向在COH期间对卵泡生长进行体积监测。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号