...
首页> 外文期刊>Graefe's archive for clinical and experimental ophthalmology: Albrecht von Graefes Archiv fur klinische und experimentelle Opthalmologie >Cirrus OCT versus Spectralis OCT: differences in segmentation in fibrovascular pigment epithelial detachment.
【24h】

Cirrus OCT versus Spectralis OCT: differences in segmentation in fibrovascular pigment epithelial detachment.

机译:Cirrus OCT与Spectralis OCT:纤维血管色素上皮脱离的分割差异。

获取原文
获取原文并翻译 | 示例

摘要

BACKGROUND: Automatically measurements of retinal thickness by optical coherence tomography (OCT) facilitate the assessment of various retinal diseases.The aim of this retrospective study was to report macular thickness measurements in eyes with vascular pigment epithelial detachment (PED) due to age-related macular degeneration (AMD) by using two different commercially available spectral domain (SD) OCT instruments and to consequently point out differences in their algorithm software.systems. METHODS: OCT images of patients with vascular PED due to AMD, obtained with Cirrus and Spectralis OCT, were retrospectively analyzed. Main objectives were to observe differences in central retinal thickness (CRT) values and failures in automated threshold delineation, as well as central point thickness values obtained after manual correction of threshold lines. Scanning with the Cirrus HD OCT was performed with the 512 x 128 scan pattern; scans performed with the Spectralis OCT were 20 x 15 degree raster scans consisting of 19 high-speed line scans. RESULTS: OCT images of 34 eyes of 28 patients with a mean age of 71 years and a mean distance visual acuity (VA) of 0.70 ETDRS were analyzed. Mean central retinal thickness (CRT) was 262.38 mum +/- 133.18 (176-507 mum) in Cirrus and 337.82 mum +/- 137.75 (277-790 mum) in Spectralis scans,mainly caused by different software approaches in positioning the posterior threshold line, following the PED in Cirrus OCT whereas remaining unelevated in Spectralis OCT. There were failures in positioning the outer retinal boundary line in 50% of Cirrus scans and in 73.52% of Spectralis scans. We obtained the mean value of central point neurosensory retinal thickness of each central single scan after manual delineation, and found a significant correlation (r = 0.819, p < 0.001). CONCLUSIONS: Our study indicates that there are significant differences in CRT values in patients with vascular PED, due to different segmentation algorithms and a high error rate in automatically set threshold lines. When planning and conducting multicenter studies, one has to be especially aware of the differences in delineating threshold algorithm lines by different SD OCT devices.
机译:背景:通过光学相干断层扫描(OCT)自动测量视网膜厚度有助于评估各种视网膜疾病。这项回顾性研究的目的是报告因年龄相关性黄斑而出现血管色素上皮脱离(PED)的眼睛的黄斑厚度测量通过使用两种不同的市售光谱域(SD)OCT仪器进行变性(AMD),并指出它们在算法软件系统上的差异。方法:回顾性分析由Cirrus和Spectralis OCT获得的AMD引起的血管性PED患者的OCT图像。主要目的是观察中心视网膜厚度(CRT)值的差异和自动阈值描绘失败,以及手动校正阈值线后获得的中心点厚度值。使用Cirrus HD OCT以512 x 128扫描模式进行扫描;使用Spectralis OCT进行的扫描是20 x 15度的光栅扫描,其中包括19条高速线扫描。结果:分析了28例平均年龄为71岁,平均远视力(VA)为0.70 ETDRS的34眼的OCT图像。 Cirrus的平均视网膜中央厚度(CRT)为262.38 +/- 133.18(176-507微米),Spectralis扫描的平均视网膜中央厚度为337.82 +/- 137.75 277-790微米,这主要是由于采用不同的软件方法来定位后阈线,在Cirrus OCT中遵循PED,而在Spectralis OCT中保持不变。在50%的Cirrus扫描和73.52%的Spectralis扫描中,视网膜外边界线的定位均失败。我们获得了手动划定后每次中央单次扫描的中心点神经感觉视网膜厚度的平均值,并发现了显着的相关性(r = 0.819,p <0.001)。结论:我们的研究表明,由于不同的分割算法和自动设置阈值行中的高错误率,血管性PED患者的CRT值存在显着差异。在计划和进行多中心研究时,必须特别意识到不同SD OCT设备在描绘阈值算法线时的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号