...
首页> 外文期刊>Berliner und Munchener Tierarztliche Wochenschrift >Measurement of temperature generation in the corium of bovine claws during claw trimming with an angle grinder using different grinding and cutting disks.
【24h】

Measurement of temperature generation in the corium of bovine claws during claw trimming with an angle grinder using different grinding and cutting disks.

机译:使用不同的磨盘和切割盘,用角向磨光机修整爪子期间,测量牛爪的皮质温度。

获取原文
获取原文并翻译 | 示例
           

摘要

Correct functional claw trimming (sole horn thickness 5 mm; group I) was performed in 80 bovine hindclaws from slaughtered cows. Standardized, incorrect claw trimming (sole horn thickness 2 mm; group 2) was performed in another 80 hindclaws. Four different disks (one cutting and three grinding disks) were used. Two thermocouples were inserted into the solar corium, and the heat production on the corium was measured during claw trimming. During correct functional claw trimming with each of the 4 disks, a temperature increase in the corium with a median of ?0.3 degrees C was calculated. During incorrect claw trimming (2 mm sole horn thickness), a temperature increase with a median of ?0.3 degrees C was determined for the first 3 disks. During claw trimming using the abrasive semiflexible plastic disk, a median of 1.3 degrees C temperature increase was calculated. Comparison of the temperatures measured in the claws from groups I and II showed a significant difference between the 4 disks. Comparison of the temperature increase within each group (groups I and II) showed a significant difference between the cutting disk with steel blades and the abrasive, semiflexible plastic disk in both groups. The highest temperatures measured were 41.5 degrees C in group I using the disk with 70% amount of fitted hard metal granulate, and 42.2 degrees C in group II (temperature increase of 10.6 degrees C) using the abrasive semiflexible plastic disk. Under the experimental conditions of this study, only a very slight thermogenesis was observed when the functional and correct claw trimming using the 4 tested disks was performed. This slight thermogenesis should not cause thermic injury of the corium. By trimming the sole horn incorrectly (2 mm), the measured heat generation in the corium was minor, without danger of thermic insult, except for using the disk with 70% fitted hard metal granulate and the abrasive semiflexible plastic disk. It was unlikely that a short-term temperature increase of 10.6 degrees C could cause thermic insults on the solar corium..
机译:在来自屠宰母牛的80头牛后爪中进行了正确的功能性爪修剪(单角厚5毫米; I组)。在另外80个后爪中进行了标准化的,不正确的爪修剪(单角厚2 mm;第2组)。使用了四个不同的盘(一个切割盘和三个研磨盘)。将两个热电偶插入太阳能日光浴中,并在修整爪期间测量在电热中的热量。用4个盘片中的每一个进行正确的功能性爪修整时,计算出皮质中的温度升高,中间值约为0.3摄氏度。在不正确的爪修整过程中(鞋底角厚为2 mm),对前3个圆盘确定温度升高,中间值约为0.3摄氏度。在使用磨料半柔性塑料盘修整爪子的过程中,计算出温度升高了1.3摄氏度。比较第一组和第二组的爪中测得的温度,发现4个圆盘之间存在显着差异。比较每组(I组和II组)内的温度升高情况,表明两组中带有钢刀片的切割盘与具有磨蚀性的半柔韧性塑料盘之间存在显着差异。使用装有70%硬质金属颗粒的圆盘,在I组中测得的最高温度为41.5℃,使用磨料半柔性塑料圆盘,在II组中,测得的最高温度为42.2℃(温度升高10.6℃)。在这项研究的实验条件下,当使用4个测试盘进行功能性和正确的修整爪时,仅观察到非常轻微的生热现象。这种轻微的生热作用不应引起皮质的热损伤。通过错误地修整鞋底角(2毫米),测得的皮质中的热量很小,没有热损伤的危险,除了使用装有70%硬质金属颗粒的磨盘和具有磨蚀性的半柔性塑料磨盘。 10.6摄氏度的短期温度升高不太可能会导致对太阳皮质的热侮辱。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号