Aims: To evaluate the feasibility and the reliability of hysterosalpingo-foam sonography (HyFoSy) using gel foam in the assessment of tubal patency. Methods: Nonrandomized, observational, academic and single-center study of 20 women being investigated because of subfertility and scheduled for a laparoscopy with chromopertubation. A detailed description of HyFoSy with a newly developed gel foam is given in the way it proved to be most efficient in our hands. The results of HyFoSy are compared to the data regarding tubal patency testing during laparoscopy by chromopertubation. Results: All 20 HyFoSy were technically successful. Four of the 40 tubes, 1 right tube and 3 left tubes, were not patent at HyFoSy (3 tubes with proximal block and 1 tube with distal block). There was a 100% agreement between tubal patency data according to HyFoSy testing and laparoscopic chromopertubation testing. Conclusion: HyFoSy is both feasible and accurate in the diagnosis of tubal patency.
机译:目的:评估使用凝胶泡沫进行输卵管通畅性评估的子宫输卵管海绵超声(HyFoSy)的可行性和可靠性。方法:非生育,观察性,学术性和单中心研究针对20位因生育力不足而进行调查的妇女,并计划进行腹腔镜胆囊切除术。 HyFoSy与新开发的凝胶泡沫的详细描述以证明在我们手中最有效的方式给出。将HyFoSy的结果与通过腹腔镜操作在腹腔镜检查中输卵管通畅性测试的数据进行比较。结果:所有20种HyFoSy在技术上均成功。在HyFoSy中,40根管中的4根,其中1根右管和3根左管在专利权方面不获专利(3根管带近端阻滞,1根管带远端阻滞)。根据HyFoSy测试,输卵管通畅性数据与腹腔镜层析操作之间有100%的一致性。结论:HyFoSy在诊断输卵管通畅中既可行又准确。