Assessment of forearm vasodilator responses to acetylcholine and albuterol by strain gauge plethysmography: reproducibility and influence of strain gauge placement.

机译:通过应变仪体积描记法评估前臂血管舒张剂对乙酰胆碱和沙丁胺醇的反应:可重复性和应变仪放置的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

AIMS: To determine the within-subject reproducibility of the forearm blood flow response to acetylcholine and the beta2-adrenoceptor agonist albuterol as measured by strain gauge plethysmography. To examine the influence of strain gauge placement on these responses. METHODS: Vasodilator response to brachial artery infusion of drugs was assessed by strain gauge plethysmography in six healthy men on each of three occasions separated by 1 week. Strain gauges were placed on both arms at the point of maximum diameter. On the infused arm two further gauges were positioned approximately 4 cm proximal and distal to the middle gauge. RESULTS: Within-subject coefficients of variation (WCV) of absolute blood flow responses for each dose of acetylcholine (7.5, 15, 30 micrograms min(-1)) ranged from 24% to 27%, as compared with WCV values of 41% to 62% for the percentage changes in blood flow ratio (infused : noninfused arm). For albuterol (0.3, 1, 3 micrograms min(-1)) the corresponding WCV values were 16% to 19% and 30% to 55% for absolute blood flow and percentage change in blood flow ratio, respectively. WCV for the area under dose-response curve (AUC) for absolute blood flow was 18% and 13% for acetylcholine and albuterol, respectively. Vasodilator responses were similar whether recorded proximal to or at the point of maximal forearm circumference. Distal strain gauge misplacement underestimated responses and the difference was greater for acetylcholine than for albuterol. CONCLUSIONS: In healthy men, the WCV for responses expressed as absolute blood flow, to acetylcholine and albuterol ranges from 16% to 27%.
机译:目的:通过应变片体积描记法测定前臂血流对乙酰胆碱和β2-肾上腺素受体激动剂沙丁胺醇反应的受试者体内可重复性。要检查应变仪放置对这些响应的影响。方法:通过应变片体积描记法评估六名健康男性的血管扩张剂对肱动脉灌注药物的反应,每3次间隔1周。将应变仪放在最大直径处的两个臂上。在注入的手臂上,将另外两个量规放置在距中间量规近端和远端约4 cm处。结果:每剂量乙酰胆碱(7.5、15、30微克min(-1))的绝对血流反应的受试者内部变异系数(WCV)范围从24%到27%,而WCV值为41%血流百分比变化百分比为62%(已输注:未输注手臂)。对于沙丁胺醇(0.3、1、3微克min(-1)),绝对血流量和血流量比率变化的相应WCV值分别为16%至19%和30%至55%。绝对血流量的剂量反应曲线下面积(AUC)的WCV,乙酰胆碱和沙丁胺醇分别为18%和13%。无论在最大前臂周长附近还是在最大前臂周长处记录,血管扩张剂的反应均相似。远端应变计错位低估了反应,乙酰胆碱的差异大于沙丁胺醇。结论:在健康男性中,WCV对乙酰胆碱和沙丁胺醇的绝对血流量的响应范围为16%至27%。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号