The photogrammetric utility of an Agfa Studio Scan II si flatbed colour scanner was examined. The scanner has a 400 ppi horizontal and 800 ppi vertical optical resolution with a pixel size of 64 μm by 32 μm. Systematic linear and non-linear distortions in the scanned images were observed, indicating the need for calibration. The calibration was done with the assistance of a distortion model, which produced a scanner distortion atlas. Distortions in the image coordinates were found by directly scanning a glass calibration grid-plate. In the absence of corrective adjustments, the measured distortions produced deviations of 0.6% or less from the object coordinates. For this particular scanner the tilt of the scanner head appears to be about 6.0 arcminutes, with a scaling distortion in the x-direction of 0.9941 and 0.9992 in the y-direction. The periodic distortion appears to have an amplitude of 1.6 pixels, and a wavelength of 4.9 cm. There appears to be no aliasing in the periodic distortion measurements.
机译:检查了Agfa Studio Scan II si平板彩色扫描仪的摄影测量实用程序。扫描仪的水平光学分辨率为400 ppi,垂直光学分辨率为800 ppi,像素尺寸为64μmx 32μm。在扫描图像中观察到系统的线性和非线性失真,表明需要校准。借助变形模型完成校准,该模型产生了扫描仪变形图集。通过直接扫描玻璃校准栅板发现图像坐标中的失真。在没有校正调整的情况下,所测得的变形与物体坐标的偏差为0.6%或更小。对于该特定的扫描仪,扫描仪头的倾斜似乎约为6.0弧分,在x方向的缩放比例失真为0.9941,在y方向的缩放比例为0.9992。周期性失真似乎具有1.6像素的振幅和4.9 cm的波长。在周期性失真测量中似乎没有混叠。