首页> 外文期刊>European journal of mass spectrometry >Depression of the apparent chiral recognition ability obtained in the host–guest complexation systems by electrospray and nano-electrospray ionization mass spectrometry
【24h】

Depression of the apparent chiral recognition ability obtained in the host–guest complexation systems by electrospray and nano-electrospray ionization mass spectrometry

机译:通过电喷雾和纳米电喷雾电离质谱法在宿主-客体络合系统中获得的表观手性识别能力下降

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Chiral recognition in the host-guest complexation systems of chiral crown ether hosts and amino ester guests was thoroughly examined using the electrospray ionization (ESI) mass spectrometry/enantiomer labeled (EL)-guest method. In this method, the mass spectra of a mixture of three components in a solution, a chiral host (H), an equal amount of an (S)-enantiomer guest labeled with deuterium atoms (G_(S-dn)~+) and an unlabeled (R)-enantiomer guest (G_R~+), were measured and the relative peak intensity value [I(H + G_R)~+ / I(H + G_(S-dn))~+ = IRIS] of the host-guest complex ions, observed with an excess guest concentration, was taken to provide the chiral recognition ability of the host. In our earlier report (1996), we demonstrated that the apparent chiral recognition abilities using a mass spectrometer with a homemade ESI interface were depressed by about one tenth compared with the corresponding abilities obtained by fast-atom bombardment (FAB) MS. In the present study, the enantioselective complexation behaviors of various combinations of chiral crown hosts with chiral guests were further investigated in detail mainly using a modern commercial ESI/ion trap (IT) mass spectrometer. Consequently, it was found that the apparent IRIS values from the ESI-MS/EL-guest method changed significantly, depending upon the instrument used, and in particular, upon the ESI interfaces. Moreover, under the specific measuring conditions in ESI-IT-MS, the degrees of depression of the apparent chiral recognition abilities are roughly grouped into three classes, depending upon the number (or probably the type) of the hydrophobic substituents of the hosts. Representing the degrees by the slopes when plotting the apparent IRIS values in ESI-MS versus those in FAB-MS, the slopes for the three classes are (1) 1.0, (2) 0.7 and (3) 0.3; the higher the hydrophobicity of the hosts (and then, the host-guest complex ions), the lower the slope (the apparent enantioselectivity). Strengthening the degree of depression may be caused by an increase in the local concentration of the host close to the surface of the droplets produced during the electrospary ionization process. The chiral recognition ability (K_R / K_S) in an equilibrated solution agrees quite well with the IRIS value in FAB-MS rather than that in ESI-MS.
机译:使用电喷雾电离(ESI)质谱/对映体标记(EL)-客体方法彻底检查了手性冠醚主体和氨基酯客体的客体-客体络合系统中的手性识别。在此方法中,溶液中三种成分的混合物,手性主体(H),等量的被氘原子标记的(S)-对映体客体(G_(S-dn)〜+)和测量未标记的(R)-对映体客体(G_R〜+),并测量其相对峰强度值[I(H + G_R)〜+ / I(H + G_(S-dn))+以过量的客体浓度观察到的宿主-客体复合离子被用来提供宿主的手性识别能力。在我们较早的报告(1996年)中,我们证明了使用具有自制ESI接口的质谱仪的表观手性识别能力比通过快速原子轰击(FAB)MS获得的相应能力降低了约十分之一。在本研究中,主要使用现代商业ESI /离子阱(IT)质谱仪进一步详细研究了手性冠主体与手性客体的各种组合的对映选择性络合行为。因此,发现根据所使用的仪器,特别是根据ESI接口,ESI-MS / EL-guest方法的表观IRIS值发生了显着变化。而且,在ESI-IT-MS中的特定测量条件下,表观手性识别能力的降低程度大致取决于主体的疏水取代基的数目(或可能的类型)分为三类。当绘制ESI-MS中的表观IRIS值与FAB-MS中的表观IRIS值时,用斜率表示度,这三类的斜率分别为(1)1.0,(2)0.7和(3)0.3;主体(然后是主体-客体复合离子)的疏水性越高,斜率越低(表观对映选择性)。凹陷程度的增强可能是由于在电喷雾电离过程中产生的液滴表面附近的主体局部浓度增加所致。平衡溶液中的手性识别能力(K_R / K_S)与FAB-MS而非ISI-MS中的IRIS值非常吻合。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号