...
首页> 外文期刊>European journal of mass spectrometry >Detection of dehydroepiandrosterone misuse by means of gas chromatography-combustion-isotope ratio mass spectrometry
【24h】

Detection of dehydroepiandrosterone misuse by means of gas chromatography-combustion-isotope ratio mass spectrometry

机译:气相色谱-燃烧-同位素比质谱法检测脱氢表雄酮滥用

获取原文
获取原文并翻译 | 示例

摘要

According to World Anti-Doping Agency (WADA) rules (WADA Technical Document-TD2004EAAS) urine samples containing dehydroepiandrosterone (DHEA) concentrations greater than 100 ng mL(-1) shall be submitted to isotope ratio mass spectrometry (IRMS) analysis. The threshold concentration is based on the equivalent to the glucuronide, and the DHEA concentrations have to be adjusted for a specific gravity value of 1.020. In 2006, 11,012 doping control urine samples from national and international federations were analyzed in the Cologne doping control laboratory, 100 (0.9%) of them yielding concentrations of DHEA greater than 100 ng mL(-1). Sixty-eight percent of the specimens showed specific gravity values higher than 1.020, 52% originated from soccer players, 95% were taken in competition, 85% were male urines, 99% of the IRMS results did not indicate an application of testosterone or related prohormones. Only one urine sample was reported as an adverse analytical finding having 319 ng mL(-1) DHEA (screening result), more than 10,000 ng mL(-1) androsterone and depleted carbon isotope ratio values for the testosterone metabolites androsterone and etiocholanolone. Statistical evaluation showed significantly different DHEA concentrations between specimens taken in- and out-of-competition, whereas females showed smaller DHEA values than males for both types of control. Also a strong influence of the DHEA excretion on different sport disciplines was detectable. The highest DHEA values were detected for game sports (soccer, basketball, handball, ice hockey), followed by boxing and wrestling. In 2007, 6622 doping control urine samples were analyzed for 3 alpha,5-cyclo-5 alpha-androstan-6 beta-ol-17-one (3 alpha,5-cyclo), a DHEA metabolite which was described as a useful gas chromatography-mass spectrometry (GC-MS) screening marker for DHEA abuse. Nineteen urine specimens showed concentrations higher than the suggested threshold of 140 ng mL-1, six urine samples yielded additionally DHEA concentrations higher than 100 ng mL(-1), none of them showing positive IRMS findings. These results should be taken into consideration in future discussions about threshold values for endogenous steroids in doping control.
机译:根据世界反兴奋剂机构(WADA)规则(WADA技术文档-TD2004EAAS),应将含有脱氢表雄酮(DHEA)浓度大于100 ng mL(-1)的尿液样品进行同位素比质谱(IRMS)分析。阈值浓度基于与葡萄糖醛酸苷的当量,必须将DHEA浓度调整为1.020的比重值。 2006年,在科隆兴奋剂控制实验室对来自国家和国际联合会的11,012个兴奋剂控制尿液样品进行了分析,其中100(0.9%)产生的DHEA浓度大于100 ng mL(-1)。 68%的样本显示比重值高于1.020,52%来自足球运动员,95%来自比赛,85%是男性尿液,99%的IRMS结果未表明使用睾丸激素或相关物质激素。据报告只有一个尿液样品为不良分析发现,具有319 ng mL(-1)DHEA(筛选结果),大于10,000 ng mL(-1)的雄甾烷酮和睾丸激素代谢产物雄甾酮和乙胆醇酮的碳同位素比值耗尽。统计学评估显示,在两种类型的对照中,在比赛中和比赛外采集的样本之间的DHEA浓度差异显着,而女性的DHEA值则比男性小。 DHEA排泄物对不同运动学科的影响也很明显。在运动项目(足球,篮球,手球,冰球)中检测到最高的DHEA值,然后进行拳击和摔跤。 2007年,对6622个兴奋剂对照尿液样品进行了3α,5-cyclo-5 alpha-androstan-6 beta-ol-17-one(3 alpha,5-cyclo)的分析,DHEA代谢物被描述为有用气体DHEA滥用的色谱-质谱(GC-MS)筛选标记。 19个尿液样本显示浓度高于建议的140 ng mL-1阈值,另外六个尿液样本产生的DHEA浓度也高于100 ng mL(-1),但均未显示出IRMS阳性结果。在有关掺杂控制中内源性类固醇的阈值的未来讨论中应考虑这些结果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号