首页> 外文期刊>Bulletin of the Korean Chemical Society >Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)
【24h】

Measurement Uncertainty of Nicotine in Environmental Tobacco Smoke (ETS)

机译:环境烟草烟雾(ETS)中尼古丁的测量不确定度

获取原文
获取原文并翻译 | 示例
           

摘要

Nicotine is the main component of environmental tobacco smoke, and its presence in indoor air is widely used as a secondhand-smoke indicator. Environmental tobacco smoke is a major source of indoor air pollution, but sufficient investigation of the uncertainty of its measurement, which mirrors the reliability of nicotine measurement, has not been performed. We calculated the uncertainty of measurement of indoor air nicotine concentration at low, medium, and high concentrations of 11.3798,10.1977,98.3768 ug/m3, respectively, and we employed the Guide to the Expression of Uncertainty in Measurements (GUM), proposed by the International Organization for Standardization (ISO). The factors considered in determining the uncertainty were uncertainty of the calibration curve (calibration curve and repeated measurements), desorption efficiency, extraction volume, and sampling airflow (accuracy and acceptable limits of flowmeter). The measurement uncertainty was highest at low concentrations; the expanded measurement uncertainty is 0.9435 ug/m3 and is represented as a relative uncertainty of 63.38%. At medium and high (concentrations, the relative uncertainty was 13.1% and 9.1%, respectively. The uncertainty of the calibration curve was largest for low indoor nicotine concentrations. To increase reliability of measurement in assessing the effect of secondhand smoke, measures such as increasing the sample injection rate (1 uL or more), increasing sampling volume to increase collected nicotine, and using gas chromatography-mass spectrometry (GC/MS) or GC/MS/MS, which has a lower quantitation threshold, rather than gas chromatography with nitrogen phosphorous detector, should be considered.
机译:尼古丁是环境烟草烟雾的主要成分,其在室内空气中的存在被广泛用作二手烟指示器。环境烟草烟雾是室内空气污染的主要来源,但是尚未对其烟熏度的不确定性进行充分调查,这反映了尼古丁烟熏度的可靠性。我们计算了低,中和高浓度分别为11.3798,10.1977,98.3768 ug / m3时室内空气烟碱浓度的测量不确定度,并采用了由测量机构提出的测量不确定度表示指南(GUM)。国际标准化组织(ISO)。确定不确定性时考虑的因素包括校准曲线(校准曲线和重复测量)的不确定性,解吸效率,提取量和采样气流(流量计的准确性和可接受的极限)。在低浓度下,测量不确定度最高。扩展后的测量不确定度为0.9435 ug / m3,相对不确定度为63.38%。在中浓度和高浓度(相对浓度)下,相对不确定度分别为13.1%和9.1%。对于低室内尼古丁浓度,校准曲线的不确定度最大。为了提高评估二手烟影响的测量的可靠性,应采取以下措施:样品进样速率(1 uL或更高),增加采样量以增加收集的尼古丁,并使用定量阈值较低的气相色谱-质谱(GC / MS)或GC / MS / MS,而不是采用应考虑使用氮磷探测器。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号