首页> 外文期刊>Experimental Thermal and Fluid Science: International Journal of Experimental Heat Transfer, Thermodynamics, and Fluid Mechanics >Augmentation of single-phase forced convection heat transfer in tightly arrayed rod bundle with twist-vane spacer grid
【24h】

Augmentation of single-phase forced convection heat transfer in tightly arrayed rod bundle with twist-vane spacer grid

机译:螺旋叶片隔栅在紧密排列的棒束中增强单相强制对流换热

获取原文
获取原文并翻译 | 示例
       

摘要

The investigation on the augmentation of convection heat transfer of water rod bundle flow was performed experimentally. The 4 x 4 tightly arrayed rod bundle with narrow gap was tested and its P/D (Pitch-to-Diameter ratio) was similar to 1.08. As the spacer grid, the twist-vane spacer grid was used. The axial mean bundle-flow velocity was U similar to 1.0 m/s, and the corresponding Reynolds number was similar to 10,400. Circumferential and axial distributions of rod-wall temperatures were measured. Upstream of twist-vane spacer grid, the rod-wall temperature at the subchannel center was measured to be lower than that at the rod-gap center. Downstream of twist-vane spacer grid, the rod-wall temperature toward the tip of twist-vane was lowest, which might be due to the deflected flow caused by twist-vane. The twist-vane spacer grid enhanced significantly the convection heat transfer in the tight-lattice rod bundle, and its maximum enhancement value was similar to 77% near the downstream of spacer grid. Based on the present experimental data, the previous correlations of Nusselt number enhancement were compared and assessed. Then, the enhancement correlation of convection heat transfer for the twist-vane spacer grid in the tightly arrayed rod bundle was proposed. (C) 2016 Elsevier Inc. All rights reserved.
机译:实验研究了水棒束流对流换热的增加。测试了具有窄间隙的4 x 4紧密排列的棒束,其P / D(螺距与直径之比)接近1.08。作为间隔格,使用了旋片间隔格。轴向平均束流速度U约为1.0 m / s,相应的雷诺数约为10400。测量了杆壁温度的周向和轴向分布。在旋片式隔栅的上游,测得在子通道中心的杆壁温度低于在杆间隙中心的杆壁温度。在扭转叶片隔栅的下游,朝向扭转叶片尖端的杆壁温度最低,这可能是由于扭转叶片引起的流量偏斜所致。扭曲叶片隔栅显着增强了紧密晶格棒束中的对流传热,其最大增强值接近于隔栅下游附近的77%。根据目前的实验数据,比较并评估了Nusselt数增强以前的相关性。然后,提出了紧密排列的棒束中扭叶式隔栅的对流换热的增强相关性。 (C)2016 Elsevier Inc.保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号