首页> 外文期刊>European journal of ophthalmology >Changes in higher order aberrations after wavefront-guided PRK for correction of low to moderate myopia and myopic astigmatism: Two-year follow-up.
【24h】

Changes in higher order aberrations after wavefront-guided PRK for correction of low to moderate myopia and myopic astigmatism: Two-year follow-up.

机译:波前引导的PRK矫正中低度近视和近视散光后高阶像差的变化:两年随访。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE. To assess efficacy, safety, and changes in higher order aberrations after wavefront-guided photorefractive keratectomy (PRK) in comparison with conventional PRK for low to moderate myopia with myopic astigmatism using a WASCA Workstation with the MEL 70 G-Scan excimer laser. METHODS. A total of 126 myopic or myopic-astigmatic eyes of 112 patients were included in this retrospective study. Patients were divided into two groups: Group 1, the study group; and Group 2, the control group. Group 1 consisted of 78 eyes treated with wavefront-guided PRK. Group 2 consisted of 48 eyes treated with spherocylindrical conventional PRK. RESULTS. Two years postoperatively, in Group 1, 5% of eyes achieved an uncorrected visual acuity (UCVA) of 0.05; 69% achieved a UCVA of 0.00; 18% of eyes experienced enhanced visual acuity of -0.18 and 8% of -0.30. In Group 2, 8% of eyes achieved a UCVA of 0.1; 25% achieved a UCVA of 0.05; and 67% achieved a UCVA of 0.00 according to logMAR calculation method. Total higher-order root-mean square increased by a factor 1.18 for Group 1 and 1.6 for Group 2. There was a significant increase of coma by a factor 1.74 in Group 2 and spherical aberration by a factor 2.09 in Group 1 and 3.56 in Group 2. CONCLUSIONS. The data support the safety and effectiveness of the wavefront-guided PRK using a WASCA Workstation for correction of low to moderate refractive errors. This method reduced the number of higher order aberrations induced by excimer laser surgery and improved uncorrected and spectacle-corrected visual acuity when compared to conventional PRK.
机译:目的。与传统PRK相比,使用WASCA工作站和MEL 70 G-Scan准分子激光与传统PRK相比,评估波前引导光折射角膜切削术(PRK)后的疗效,安全性和高阶像差的变化。方法。这项回顾性研究共纳入112例患者的126只近视眼或近视散光眼。患者分为两组:第一组,研究组;第二组,第二组。第2组,即对照组。第1组由78眼接受波前引导的PRK治疗。第2组由48只眼球常规PRK治疗。结果。术后两年,在第1组中,有5%的眼睛的未矫正视敏度(UCVA)为0.05; 69%的UCVA为0.00; 18%的眼睛的视力增强了-0.18,而8%的视力-0.30。在第2组中,有8%的眼睛的UCVA为0.1; 25%的UCVA为0.05;根据logMAR计算方法,有67%的用户的UCVA为0.00。第一组的总高阶均方根增加了1.18倍,而第二组则增加了1.6倍。第二组的昏迷显着增加了1.74倍,第1组的球差增加了2.09倍,第3组增加了3.56倍2.结论。数据支持使用WASCA工作站校正低至中等屈光不正的波前引导PRK的安全性和有效性。与传统的PRK相比,此方法减少了受激准分子激光手术引起的高阶像差的数量,并提高了未矫正和眼镜矫正的视敏度。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号