首页> 外文期刊>European journal of ophthalmology >Twelve years' continuous wear of the same therapeutic soft contact lens: a case report.
【24h】

Twelve years' continuous wear of the same therapeutic soft contact lens: a case report.

机译:相同的治疗性软性隐形眼镜连续佩戴十二年:一例。

获取原文
获取原文并翻译 | 示例
       

摘要

PURPOSE: To describe a case of a patient who had worn the same therapeutic soft contact lens (TSCL) continuously for twelve years, since he had failed to attend normal follow-up visits. METHODS: Microbiological histological and scanning electron microscopic (SEM) studies of conjunctiva, cornea and TSCL were done. RESULTS: Cultures were negative. Corneal histology revealed mild stromal edema and mild epithelial parakeratosis. Corneal SEM was remarkable for the preservation to some extent of normal corneal epithelial specialization with microtricae and microvillae. SEM of the TSCL showed a ruffed multi-layer surface with several cracks including different types of cells. CONCLUSIONS: The patient showed surprising tolerance to the continuous wear of the same contact lens for 12 years.
机译:目的:描述一例患者,因为他没有参加正常的随访,所以连续佩戴了相同的治疗性软性隐形眼镜(TSCL)达十二年。方法:进行了结膜,角膜和TSCL的微生物组织学和扫描电子显微镜(SEM)研究。结果:文化为阴性。角膜组织学检查发现轻度间质水肿和轻度上皮角化不全。角膜扫描电镜在保留一定程度的正常角膜上皮细微组织和微绒毛方面具有显着意义。 TSCL的SEM显示多层表面凹凸不平,带有多个裂缝,包括不同类型的细胞。结论:该患者对同一隐形眼镜连续佩戴12年表现出惊人的耐受性。