首页> 外文期刊>European journal of ophthalmology >Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects.
【24h】

Intraobserver reproducibility of retinal nerve fiber layer measurements using scanning laser polarimetry and optical coherence tomography in normal and ocular hypertensive subjects.

机译:在正常和高眼压的受试者中,使用扫描激光偏振法和光学相干断层扫描技术测量视网膜神经纤维层的观察者可重复性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To evaluate quantitatively the intraobserver reproducibility of measurements of the retinal nerve fiber layer (RNFL) in healthy subjects and an ocular hypertensive population using two nerve fiber analyzers. METHODS: Sixty eyes of normal (n=30) and ocular hypertensive subjects (n=30) were consecutively recruited for this study and underwent a complete ophthalmologic examination and achromatic automated perimetry. RNFL were measured using scanning laser polarimeter (GDx-VCC) and optical coherence tomography (OCT Model 3000). Reproducibility of the RNFL measurements obtained with both nerve fiber analyzers were compared using the coefficient of variation. RESULTS: In both groups the authors found fair correlations between the two methods in all ratio and thickness parameters. The mean coefficient of variation for measurement of the variables ranged from 2.24% to 13.12% for GDx-VCC, and from 5.01% to 9.24% for OCT Model 3000. The authors could not detect any significant differences between healthy and ocular hypertensive eyes, although in normal eyes the correlations improved slightly. Nevertheless, the test-retest correlation was slightly better for GDx-VCC than for OCT Model 3000 (5.55% and 7.11%, respectively). CONCLUSIONS: Retinal mapping software of both nerve fiber analyzers allows reproducible measurement of RNFL in both healthy subjects and ocular hypertensive eyes, and shows fair correlations and good intraobserver reproducibility. However, in our study, GDx showed a better test-retest correlation.
机译:目的:使用两个神经纤维分析仪定量评估健康受试者和高眼压人群中视网膜神经纤维层(RNFL)测量值的观察者再现性。方法:本研究连续招募了60眼正常(n = 30)眼和高血压受试者(n = 30),并进行了完整的眼科检查和消色差自动视野检查。 RNFL使用扫描激光旋光仪(GDx-VCC)和光学相干断层扫描(OCT 3000型)进行测量。使用变异系数比较了使用两种神经纤维分析仪获得的RNFL测量值的可重复性。结果:在两组中,作者均发现两种方法在所有比率和厚度参数上都具有合理的相关性。对于GDx-VCC,测量变量的平均变异系数在2.24%至13.12%之间,对于OCT 3000型,其平均变异系数在5.01%至9.24%之间。尽管存在健康和高眼压眼,但作者无法检测到任何显着差异。在正常的眼睛中,相关性略有改善。但是,GDx-VCC的重测相关性比OCT 3000型更好(分别为5.55%和7.11%)。结论:两种神经纤维分析仪的视网膜作图软件都可以在健康受试者和高眼压眼中对RNFL进行可重复的测量,并显示出合理的相关性和良好的观察者内可重复性。但是,在我们的研究中,GDx显示出更好的重测相关性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号