...
首页> 外文期刊>European journal of ophthalmology >Detecting an event of progression using glaucoma probability score and the stereometric parameters of Heidelberg Retina Tomograph 3
【24h】

Detecting an event of progression using glaucoma probability score and the stereometric parameters of Heidelberg Retina Tomograph 3

机译:使用青光眼概率评分和海德堡视网膜断层扫描仪3的立体参数检测进展事件

获取原文
获取原文并翻译 | 示例
           

摘要

Purpose: To evaluate the correlation of the change in glaucoma probability score (GPS) and the stereometric optic nerve head (ONH) parameters of the Heidelberg Retina Tomograph (HRT)3 to an event of glaucomatous progression observed with stereoscopic ONH photography. Methods: The subjects for this retrospective follow-up study were monitored with the HRT and stereoscopic ONH photographs. Stable, high-quality imaging and at least 18 months of follow-up was required. The topography examinations were acquired using HRT II and calculated with HRT3 software. The event of progression was determined by masked evaluation of stereoscopic ONH photographs. Results: A total of 476 eyes of 342 subjects met the inclusion criteria. All the examinations with HRT II were backwards compatible with either the GPS or the stereometric parameters of HRT3. The highest statistical significance for the correlation with progression was observed in the change in cup volume and cup-disc area ratio (p<0.0005). The vertical cup:disc ratio was the parameter with the largest area under the receiver operating characteristics curve (AUC = 0.696). The AUC calculated for the change in GPS was 0.541. The GPS showed no statistically significant correlation with progression (p = 0.213). Conclusions: Detecting an event of glaucomatous progression should not be based solely on the change in GPS or the stereometric parameters of the HRT. The good backwards compatibility between HRT II and HRT3 should allow the detection of a trend of glaucomatous progression even when changing from HRT II to HRT3 during the follow-up of glaucoma.
机译:目的:评估海德堡视网膜断层扫描(HRT)3的青光眼概率评分(GPS)和立体视神经头(ONH)参数的变化与通过立体ONH摄影观察到的青光眼进展的相关性。方法:使用HRT和立体ONH照片对这项回顾性随访研究的受试者进行监测。需要稳定,高质量的成像以及至少18个月的随访。使用HRT II获取地形检查,并使用HRT3软件进行计算。进展的事件通过对立体ONH照片的蒙版评估来确定。结果:342名受试者中的476只眼睛符合纳入标准。使用HRT II进行的所有检查均向后兼容GPS或HRT3的立体参数。在杯体积和杯碟面积比的变化中,观察到与进展相关的最高统计学显着性(p <0.0005)。垂直杯:盘比是接收器工作特性曲线下最大面积的参数(AUC = 0.696)。计算出的GPS变化的AUC为0.541。 GPS显示与进展无统计学显着相关性(p = 0.213)。结论:检测青光眼进展的事件不应仅基于GPS的变化或HRT的立体参数。即使在青光眼的随访期间从HRT II变为HRT3,HRT II和HRT3之间的良好向后兼容性也应能够检测出青光眼进展的趋势。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号