PURPOSE: To evaluate prior studies including a glaucoma drainage device and to describe the timing and incidence of conjunctival exposure. A meta-analysis of previously published articles. METHODS: Articles included were prospective, single cohort, or comparative parallel design, with a mean treatment period of at least 3 months and at least 30 patients per treatment arm. We limited our analysis to studies that evaluated the most common devices, including Ahmed, Baerveldt, and Molteno. RESULTS: We included 38 studies containing 45 treatment arms (16 Ahmed, 12 Baerveldt, and 17 Molteno). These studies included 3,105 patients and 3,255 eyes with an average follow-up of 26.1+/-3.3 months. The overall incidence of exposure was 2.0+/-2.6% (n=64) of eyes with an average exposure/month of 0.09+/-0.14%. There was no significant correlation between study length and incidence of exposure (p=0.11), although multivariate regression analysis identified length of follow-up as a risk factor for exposure (p=0.001). Among individual drainage devices, there was no significant difference in the incidence of exposure (p=0.22) or percent exposure per month (p=0.18). In addition, no difference existed in the incidence of exposure between sizes for the Baerveldt 250, 350 or 500 mm (p=0.7), number of plates for the Molteno Single or Double (p=0.3), nor between the composition of the Ahmed Silicone or Polypropylene (p=0.7). CONCLUSIONS: This study suggests that tube exposure of glaucoma implants is unusual and the incidence does not differ between the Ahmed, Baerveldt, and Molteno implants. However, exposure appears to occur at any time within the first 5 years following implantation.
机译:目的:评估包括青光眼引流装置在内的先前研究,并描述结膜暴露的时间和发生率。对以前发表的文章进行荟萃分析。方法:纳入的文章为前瞻性,单队列或比较平行设计,平均治疗期至少3个月,每个治疗组至少30名患者。我们将分析仅限于评估最常见设备的研究,包括艾哈迈德(Ahmed),巴斯夫(Baerveldt)和莫尔泰诺(Molteno)。结果:我们纳入了38个研究,其中包含45个治疗组(16个艾哈迈德,12个巴尔维尔特和17个莫尔泰诺)。这些研究包括3105例患者和3255眼,平均随访26.1 +/- 3.3个月。暴露的总发生率为2.0 +/- 2.6%(n = 64)眼,每月平均暴露为0.09 +/- 0.14%。尽管多元回归分析将随访时间长短作为暴露的风险因素(p = 0.001),但研究时间和暴露发生率之间没有显着相关性(p = 0.11)。在单个排水设备之间,暴露的发生率(p = 0.22)或每月的暴露百分比(p = 0.18)均无显着差异。此外,Baerveldt 250、350或500 mm的尺寸(p = 0.7)之间,Molteno单面或双面的板数(p = 0.3)之间,Ahmed的成分之间的暴露发生率均无差异。有机硅或聚丙烯(p = 0.7)。结论:这项研究表明,青光眼植入物的管子暴露是不寻常的,并且艾哈迈德,Baerveldt和Molteno植入物的发生率没有差异。但是,似乎在植入后的头5年内的任何时间都有暴露。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号