...
首页> 外文期刊>European Journal of Obstetrics, Gynecology and Reproductive Biology: An International Journal >Reliability of examining the external iliac artery with Doppler ultrasound in the first trimester and its relationship with maternal blood pressure and uterine artery blood flow
【24h】

Reliability of examining the external iliac artery with Doppler ultrasound in the first trimester and its relationship with maternal blood pressure and uterine artery blood flow

机译:孕早期用多普勒超声检查外动脉的可靠性及其与产妇血压和子宫动脉血流的关系

获取原文
获取原文并翻译 | 示例
           

摘要

Objective: To explore the reliability of examining the external iliac artery (EIA) at 11+0 to 13+6 weeks of gestation with Doppler ultrasound and its relationship with maternal characteristics and uterine artery blood flow. Study design: Cross-sectional study of 451 pregnant women undergoing an ultrasound scan in the first trimester. Mean pulsatility index (PI) of both EIAs was correlated to maternal characteristics (maternal age, parity, body mass index and mean arterial blood pressure (MAP)) and ultrasound parameters (crown-rump length (CRL) and mean uterine artery PI). Mean EIA-PI was logarithmically transformed to perform multiple linear regression analysis. The intra- and inter-observer reproducibilities of EIA-PI were examined. Results: Satisfactory flow velocity waveforms were obtained from both EIA in all patients. There is a significant negative correlation between mean EIA pulsatility index and maternal blood pressure. Multiple linear regression analysis showed an independent contribution of MAP to log EIA-PI (mean) (standardized regression coefficient = -0.20, 95% CI: -0.005 to -0.002). The intra-class correlation coefficients (ICCs) for intraobserver and interobserver reproducibility were 0.94 (95% CI, 0.88-0.97) and 0.87 (0.76-0.94) respectively. Conclusions: Examining blood flow in the external iliac artery using Doppler ultrasound in the first trimester is feasible and reproducible. There is a negative correlation between mean EIA-PI and maternal blood pressure.
机译:目的:探讨多普勒超声检查在妊娠11 + 0至13 + 6周时检查外动脉(EIA)的可靠性,及其与孕妇特征和子宫动脉血流的关系。研究设计:451例孕妇在孕早期进行了超声扫描,进行了横断面研究。两种EIA的平均搏动指数(PI)与产妇特征(产妇年龄,胎次,体重指数和平均动脉血压(MAP))和超声参数(冠臀长(CRL)和平均子宫动脉PI)相关。对数平均EIA-PI进行对数转换以执行多元线性回归分析。检查了EIA-PI在观察者内和观察者间的可重复性。结果:所有患者的两个EIA均获得令人满意的流速波形。平均EIA搏动指数与孕妇血压之间存在显着负相关。多元线性回归分析显示MAP对log EIA-PI(平均值)有独立贡献(标准化回归系数= -0.20,95%CI:-0.005至-0.002)。观察者内和观察者间再现性的类内相关系数(ICC)分别为0.94(95%CI,0.88-0.97)和0.87(0.76-0.94)。结论:妊娠早期使用多普勒超声检查外动脉血流是可行且可重复的。平均EIA-PI与母亲血压之间呈负相关。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号