A total of 248 of 248 of cadaveric sigmoid diverticula could be inverted by means of vacuum or forceps. The forces required for inversion ranged from 0.28 to 0.47 N (median, 0.37 N). Twenty-four spiked O-rings were delivered in 6 living pigs to produce 24 inverted pseudodiverticula. One animal died the day after the procedure of a pulmonary thromboembolism. In the remaining 5 pigs, all delivered spiked O-rings remained in place for 7 to 22 days. At necropsy, none of the inverted sites showed signs of perforation but rather full-thickness reparative scarring with ingrowth of connective tissue.
机译:248个尸体乙状结肠憩室中的248个可以通过真空或镊子倒置。反转所需的力范围为0.28至0.47 N(中值,0.37 N)。在6只活猪中分发了24个尖刺O形圈,以产生24个倒置伪憩室。肺血栓栓塞术后第二天死亡。在剩下的5头猪中,所有交付的尖刺O形圈都保留了7至22天。尸检时,没有一个倒置的部位显示出穿孔的迹象,而是结缔组织向内生长的全层修复性瘢痕。