A 64-year-old female patient underwent pancreatoduo-denectomy (PD) for a pancreatic neoplasm. Because the mass was close to the portal vein and there was a celiac trunk stenosis, aorto-hepatic artery bypass also was performed. Histologic examination showed a ductal pancreatic carcinoma (pT4 pTNl G2). On day 15 after the surgery, she developed sepsis with a pancreatic leak and wound dehis-cence with a high-output gastrojejunal leak (GJL), approximating 500 mL/day. Two months after resolution of sepsis, the high-output GJL and wound dehiscence persisted. Because of the impossibility of further surgical intervention, upper endoscopy was performed with placement of 2 overlapping, covered, self-expandable, metal-coated stents ([SEMS] Niti-S esophageal covered stent, 28 mm x 10 cm; TaeWoong Medical Co Ltd, Seoul, Korea) (A).
机译:一名64岁的女性患者因胰腺肿瘤接受了胰十二指肠切除术(PD)。由于肿块靠近门静脉并且有腹腔干狭窄,因此也进行了主动脉-肝动脉搭桥术。组织学检查显示为导管胰腺癌(pT4 pTN1 G2)。手术后第15天,她出现败血症,并伴有胰漏,伤口裂开并伴有高输出的胃空肠漏(GJL),约500 mL /天。脓毒症消退后两个月,高输出GJL和伤口裂开持续存在。由于无法进行进一步的手术干预,因此在上消化道内窥镜中放置了2个重叠的,覆盖的,可自我扩张的金属涂层支架([SEMS] Niti-S食道覆盖的支架,直径28 mm x 10 cm; TaeWoong Medical Co Ltd ,韩国首尔)(A)。