摘要

PURPOSE: Recent studies have shown that low tear phospholipid levels are associated with tear film instability in hydrophilic contact lens wearers. The concentration of secretory phospholipase A2 (sPLA2), the enzyme that hydrolyzes phospholipids, in tears is known to exceed the levels found in serum by four orders of magnitude. This study was performed to determine the levels of sPLA2 from the deposition on two different frequent-replacement contact lens materials. METHODS: Polymacon and etafilcon A contact lenses worn for 2 weeks by 16 experienced contact lens wearers were used for the analysis. Total lipids were determined by the sulfo-phospho-vanillin reaction. Phospholipids in lipid extracts were estimated by phosphorus determination with ammonium molybdate through enzymatic digestion. Total protein was measured by bicinchoninic acid analysis. Double-antibody sandwich enzyme-linked immunosorbent assay was used to determine sPLA2 concentrations. RESULTS: Total lipid deposition was found to be greater in the polymacon group (66.3+/-16.3 microg/lens) than in the etafilcon A group, although phospholipids were not detected in either group. The etafilcon A group had greater deposition of protein (3.7+/-0.7 mg/lens) than the polymacon group had. The etafilcon A group deposited statistically significantly more group IIa sPLA2 (1.1+/-0.3 microg/lens) than the polymacon group (0.07+/-0.04 microg/lens) did (P<0.001). CONCLUSIONS: There was a significant difference in the lipid and protein deposition profiles in the two lenses tested. A significant amount of sPLA2 in the deposition on contact lenses may play a role in tear film instability in hydrophilic contact lens wearers.
机译:目的:最近的研究表明,亲水性隐形眼镜佩戴者的泪液磷脂水平低与泪膜不稳定性有关。众所周知,泪液中的磷脂酶A2(sPLA2)的浓度会比血清中的水平高出四个数量级。进行这项研究是为了确定在两种不同的频繁更换隐形眼镜材料上的沉积物中sPLA2的水平。方法:使用Polymacon和etafilcon A隐形眼镜,由16名经验丰富的隐形眼镜配戴者佩戴2周进行分析。总脂质通过磺基-磷酸-香兰素反应确定。脂质提取物中的磷脂通过钼酸铵通过酶消化法测定磷来估算。通过二辛可宁酸分析测量总蛋白。用双抗体夹心酶联免疫吸附测定法测定sPLA2浓度。结果:发现聚多康康组的总脂质沉积(66.3 +/- 16.3 microg / lens)比依他菲康A组的高,尽管两组均未检出磷脂。 etafilcon A组比polymacon组具有更大的蛋白质沉积(3.7 +/- 0.7 mg / lens)。 etafilcon A组的IIa sPLA2组(1.1 +/- 0.3 microg / lens)比聚甲基康明组(0.07 +/- 0.04 microg / lens)统计学上显着增加(P <0.001)。结论:在测试的两个镜片中,脂质和蛋白质沉积特征存在显着差异。隐形眼镜上沉积物中大量的sPLA2可能在亲水性隐形眼镜佩戴者的泪膜不稳定性中起作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号