首页> 外文期刊>Eye >Validation of printed and computerised crowded Kay picture logMAR tests against gold standard ETDRS acuity test chart measurements in adult and amblyopic paediatric subjects
【24h】

Validation of printed and computerised crowded Kay picture logMAR tests against gold standard ETDRS acuity test chart measurements in adult and amblyopic paediatric subjects

机译:针对成人和弱视儿童受试者的金标准ETDRS敏锐度测试图测量结果对印刷和计算机化的拥挤Kay图片logMAR测试进行验证

获取原文
获取原文并翻译 | 示例
           

摘要

Aims The impression exists that picture acuity scores may overestimate function when subjects are switched to letter charts. This has not been systematically investigated. The aims of this study were to validate both printed crowded Kay picture (pCKP) and computerised CKP (cCKP) logMAR test acuity measurements against gold standard ETDRS letter chart scores. Methods A total of 30 adult subjects with various ophthalmic disease and 40 amblyopic children underwent test and re-test visual acuity measurements using the ETDRS chart, the pCKP logMAR test, and the cCKP acuity scores taken, using the COMPlog visual acuity measurement system. Bland and Altman methods were employed. Results Computerised and printed Kay picture acuity scores agreed well. Both Kay picture test measurements were systematically biased when compared with ETDRS chart measurements. No significant proportional bias was found. The test retest variability (TRV) of all three tests was found to be similar between ±0.14 and 0.16 logMAR in both groups. Conclusions All three tests were similarly replicable and computerised Kay pictures appear to be a valid alternative to hard copy Kay pictures. Kay picture acuity measurements were systematically biased when compared with the gold standard ETDRS. Measurement error means that differences of up to 0.16 logMAR may be observed in clinically stable patients when re-measured using the same technique. A combination of TRV and systematic bias can however lead to differences of up to 0.40 logMAR in stable amblyopic patients when switched from CKPs to ETDRS chart acuity measurements.
机译:目的印象是,当主体切换到字母图表时,图片灵敏度得分可能会高估功能。尚未对此进行系统研究。这项研究的目的是针对黄金标准ETDRS字母图得分验证印刷的拥挤的凯图片(pCKP)和计算机化的CKP(cCKP)logMAR测试敏锐度测量结果。方法共有30名患有各种眼科疾病的成年受试者和40名弱视儿童接受了ETDRS图,pCKP logMAR测试以及cCKP视力得分,并使用COMPlog视力测量系统进行了测试和重新测试。使用了Bland和Altman方法。结果计算机化和打印的Kay图像敏锐度得分一致。与ETDRS图表测量值相比,两种Kay图片测试测量值都存在系统偏差。没有发现明显的比例偏差。发现两组的所有三个测试的测试重测变异性(TRV)在±0.14和0.16 logMAR之间相似。结论所有这三个测试都具有相似的可复制性,并且计算机化的Kay图片似乎是硬拷贝Kay图片的有效替代方案。与黄金标准ETDRS相比,凯图像的敏锐度测量在系统上存在偏差。测量误差意味着当使用相同技术重新测量时,在临床稳定的患者中可能会观察到高达0.16 logMAR的差异。但是,将稳定的弱视患者从CKP切换到ETDRS图视力测量时,TRV和系统偏见的组合可能导致差异高达0.40 logMAR。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号