AimsThe outcomes of laser-assisted in situ keratomileusis (LASIK) operations performed with the Classic FEMTO LDV femtosecond laser using the plastic single-use suction ring (Ziemer Ophthalmic Systems) and the Allegretto Wave Concerto 500 Hz excimer laser (Wavelight AG) are presented in terms of accuracy, predictability, and safety of the operation.MethodsA FEMTO LDV plastic suction ring was used for flap creation in 342 eyes of 179 patients. The intended flap thickness was 90 μm. The size of the suction ring varied from 9.0 to 10.0 mm. Flap dimensions were measured and correlated to preoperative characteristics.ResultsMean flap thickness was very constant, 89.6±2.0 μm (range 84-97). In 163 bilateral operations, the second flap was 1.1 μm thinner than the one cut first (P<0.0001). Mean flap diameter was 9.4±0.2 mm (range 8.1-9.9). Mean hinge length was 3.9±0.2 mm (range 3.0-4.2). In hyperopic eyes, flap thickness correlated negatively with keratometric power K 1 and flap diameter. In hyperopic eyes, flap diameter correlated positively with spherical equivalent refraction and with keratometric power K 1 as well as hinge length both in myopic and hyperopic eyes. Complications were reported in 12 (3.5%) eyes. Complications were very mild and none of them prevented further refractive laser treatment. Two Snellen lines of corrected distance visual acuity were lost in one (0.3%) eye.ConclusionThe FEMTO LDV plastic single-use suction rings yielded accurate and reproducible flaps and were safe for the creation of thin corneal flaps.
机译:目标展示了使用塑料一次性吸环(Ziemer Ophthalmic Systems)和经典Allegretto Wave协奏曲500 Hz准分子激光(Wavelight AG)进行的经典FEMTO LDV飞秒激光执行的激光辅助原位角膜磨镶术(LASIK)手术的结果。方法:使用FEMTO LDV塑料抽吸环在179例患者的342眼中制作皮瓣。预期的翼片厚度为90μm。吸环的尺寸从9.0到10.0 mm不等。测量皮瓣尺寸并与术前特征相关。结果平均皮瓣厚度非常恒定,为89.6±2.0μm(范围84-97)。在163次双侧手术中,第二个皮瓣比第一次切开的皮瓣薄1.1μm(P <0.0001)。皮瓣平均直径为9.4±0.2 mm(范围8.1-9.9)。平均铰链长度为3.9±0.2 mm(范围3.0-4.2)。在远视眼中,皮瓣厚度与角膜屈光度K 1和皮瓣直径负相关。在远视眼中,近视眼和远视眼的皮瓣直径与球面等效屈光度和角膜屈光度K 1以及铰链长度呈正相关。据报道有12只眼(3.5%)发生并发症。并发症非常轻微,没有一个阻止进一步的屈光性激光治疗。一只(0.3%)的眼睛失去了两条矫正远视力的Snellen线。结论FEMTO LDV一次性塑料吸环可产生精确且可复制的皮瓣,可安全地形成薄角膜皮瓣。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号