Anterior and posterior corneal stroma elasticity after corneal collagen crosslinking treatment

机译:角膜胶原交联处理后角膜前,后角弹性

获取原文
获取原文并翻译 | 示例

摘要

The purpose of this project was to assess anterior and posterior corneal stromal elasticity after corneal collagen cross linking (CXL) treatment in human cadaver eyes using Atomic Force Microscopy (AFM) through indentation. Twenty four human cadaver eyes (12 pairs) were included in this study and divided into 2 groups (6 pairs per group). In both groups, the left eye (OS) served as a control (no riboflavin or CXL treatment was performed) and the right eye (OD) underwent CXL treatment (30min of riboflavin pretreatment followed by 30min of exposure to 3mW/cm2 of ultraviolet light). In group 1, the anterior stroma was exposed by manual delamination of approximately 50μm of the corneal stroma including Bowman's membrane. In group 2, the posterior stroma was exposed by delamination of the anterior 50% of the corneal stroma including Bowman's membrane. Delamination was performed after crosslinking treatment in the case of the treated eyes. In all eyes, the stromal elasticity was quantified using AFM through indentation. Young's modulus of elasticity for the anterior cornea (group 1) was 245.9±209.1kPa (range: 82.3-530.8kPa) for the untreated control eyes, and 467.8±373.2kPa (range: 157.4-1126kPa) for the CXL treated eyes. Young's modulus for the posterior cornea (group 2) was 100.2±61.9kPa (range: 28.1-162.6kPa) for the untreated control eyes and 66.0±31.8kPa (range: 31.3-101.7kPa) for the CXL treated eyes. Young's modulus of the anterior stroma significantly increased after CXL treatment (p=0.024), whereas the posterior stroma did not demonstrate a significant difference in Young's modulus after CXL treatment (p=0.170). The anterior stroma was stiffer than the posterior stroma for both the control and CXL treatment groups (p=0.077 and p=0.023, respectively). Our findings demonstrate that stiffness of the anterior corneal stroma after CXL treatment seems to increase significantly, while the posterior stroma does not seem to be affected by CXL.
机译:该项目的目的是使用原子力显微镜(AFM)通过压痕评估在尸体眼睛中角膜胶原蛋白交联(CXL)治疗后的前,后角膜基质弹性。本研究包括二十四只人尸体眼睛(12对),分为2组(每组6对)。在两组中,左眼(OS)作为对照(未进行核黄素或CXL处理),右眼(OD)进行CXL处理(核黄素预处理30分钟,然后暴露于3mW / cm2紫外线30分钟)。在第1组中,通过约50μm的包括Bowman's膜的角膜基质的手动分层暴露前基质。在第2组中,通过剥离包括鲍曼氏膜在内的50%角膜基质前部,使后部基质暴露。对于经处理的眼睛,在交联处理后进行脱层。在所有眼睛中,使用AFM通过压痕量化基质弹性。未经处理的对照眼的前角膜(第1组)的杨氏弹性模量为245.9±209.1kPa(范围:82.3-530.8kPa),而经CXL处理的眼的杨氏弹性模量为467.8±373.2kPa(范围:157.4-1126kPa)。对于未经处理的对照眼,后角膜(第2组)的杨氏模量为100.2±61.9kPa(范围:28.1-162.6kPa),对于经CXL处理的眼为66.0±31.8kPa(范围:31.3-101.7kPa)。 CXL处理后前基质的杨氏模量显着增加(p = 0.024),而CXL处理后后基质的杨氏模量没有显着差异(p = 0.170)。对于对照组和CXL治疗组,前基质比后基质硬(分别为p = 0.077和p = 0.023)。我们的发现表明,CXL治疗后角膜前基质的刚度似乎显着增加,而后基质似乎不受CXL的影响。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号