The mouse corneal thickness is very important for research into the fields of eye disease. However, the invivo corneal thickness for the entire cornea from the pupil to the limbus was not determined. We measured invivo corneal layer thicknesses in different corneal areas, from the central cornea to the limbus, in the widely used inbred C57BL/6 and BALB/c mouse strains using two-photon (2 PH) imaging. Eight corneas of the C57BL/6 or BALB/c were scanned using a 2 PH laser scanning fluorescence microscopy system. A total of 14 thicknesses of the different corneal layers, from different corneal regions, were measured using image processing software. In both C57BL/6 and BALB/c mice, the thickness of the corneal layers was inhomogeneous in different areas of the cornea, and all of the layers had their minimum thickness at the limbus. In C57BL/6 mice, the thickness of the corneal layers gradually increased from the central to the paracentral cornea, peaked at the fifth measurement point in the paracentral area, and decreased from this point to the limbus. In BALB/c mice, the thickness of the entire cornea and corneal epithelium had its maximum at the central cornea and gradually decreased from the central cornea to the peripheral cornea and to the limbus. The thickness of the corneal stroma and endothelium had its maximum at the fourth measurement point in the paracentral cornea and gradually decreased from the paracentral cornea to the limbus. The ratio of epithelial thickness to the total corneal thickness gradually decreased from the central cornea to the limbus in both C57BL/6 and BALB/c mice. The minimum ratio was observed at the fourteenth measurement point in both C57BL/6 and BALB/c mice. The ratio of stromal and endothelial to the total corneal thickness gradually increased from the central cornea to the limbus in both C57BL/6 and BALB/c mice. The maximum ratio was observed at the fourteenth measurement point in C57BL/6 mice. The ratio at the first eight measurement points was significantly lower in BALB/c than in C57BL/6 mice (P<0.05). Our study demonstrated that the thickness of the entire cornea, the corneal epithelium, the corneal stroma and the endothelium was inhomogeneous in different areas of the cornea. Moreover, all of the layers exhibited a minimum thickness at the limbus in both C57BL/6 and BALB/c mice. Furthermore, the corneal thickness in different areas varied between C57BL/6 and BALB/c mice, and the variation in thickness with respect to corneal location for these strains was dissimilar. When using the mouse as an animal model to examine the cornea, it is important to note the differences between humans and mice.
机译:小鼠角膜厚度对于研究眼疾领域非常重要。然而,尚未确定从瞳孔到角膜缘的整个角膜的体内角膜厚度。我们使用双光子(2 PH)成像技术测量了广泛使用的近交C57BL / 6和BALB / c小鼠品系中从中央角膜到角膜缘的不同角膜区域的体内角膜层厚度。使用2 PH激光扫描荧光显微镜系统扫描了八个C57BL / 6或BALB / c角膜。使用图像处理软件测量了来自不同角膜区域的不同角膜层的总共14个厚度。在C57BL / 6和BALB / c小鼠中,角膜的厚度在角膜的不同区域均不均匀,并且所有层在角膜缘均具有最小厚度。在C57BL / 6小鼠中,角膜层的厚度从中央角膜中央到中央旁角膜逐渐增加,在中央旁角膜区的第五个测量点达到峰值,然后从该点到角膜缘减小。在BALB / c小鼠中,整个角膜和角膜上皮的厚度在中央角膜处达到最大值,并从中央角膜到周围角膜和角膜缘逐渐减小。角膜基质和内皮的厚度在中央下角膜的第四个测量点处达到最大值,并从中央下角膜到角膜缘逐渐减小。在C57BL / 6和BALB / c小鼠中,从中央角膜到角膜缘,上皮厚度与角膜总厚度的比率逐渐降低。在C57BL / 6和BALB / c小鼠的第14个测量点均观察到最小比率。 C57BL / 6和BALB / c小鼠的角膜基质和内皮细胞与角膜总厚度的比率从中央角膜到角膜缘逐渐增加。在C57BL / 6小鼠的第十四个测量点观察到最大比例。 BALB / c中前八个测量点的比率显着低于C57BL / 6小鼠(P <0.05)。我们的研究表明,整个角膜,角膜上皮,角膜基质和内皮的厚度在角膜的不同区域是不均匀的。此外,在C57BL / 6和BALB / c小鼠中,所有层在角膜缘均表现出最小厚度。此外,C57BL / 6和BALB / c小鼠在不同区域的角膜厚度各不相同,并且这些菌株相对于角膜位置的厚度变化并不相似。当使用小鼠作为检查角膜的动物模型时,重要的是要注意人与小鼠之间的差异。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号