...
首页> 外文期刊>European radiology >Fast magnetic resonance imaging of the knee using a parallel acquisition technique (mSENSE): a prospective performance evaluation.
【24h】

Fast magnetic resonance imaging of the knee using a parallel acquisition technique (mSENSE): a prospective performance evaluation.

机译:使用并行采集技术(mSENSE)对膝盖进行快速磁共振成像:前瞻性性能评估。

获取原文
获取原文并翻译 | 示例

摘要

The performance of a magnetic resonance (MR) imaging strategy that uses multiple receiver coil elements and integrated parallel imaging techniques (iPAT) in traumatic and degenerative disorders of the knee and to compare this technique with a standard MR imaging protocol was evaluated. Ninety patients with suspected internal derangements of the knee joint prospectively underwent MR imaging at 1.5 T. For signal detection, a 6-channel array coil was used. All patients were investigated with a standard imaging protocol consisting of different turbo spin-echo sequences proton density (PD), T2-weighted turbo spin echo (TSE) with and without fat suppression) in three imaging planes. All sequences were repeated with an integrated parallel acquisition technique (iPAT) using the modified sensitivity encoding (mSENSE) algorithm with an acceleration factor of 2. Two radiologists independently evaluated and scored all images with regard to overall image quality, artefacts and pathologic findings. Agreement of the parallel ratings between readers and imaging techniques, respectively, was evaluated by means of pairwise kappa coefficients that were stratified for the area of evaluation. Agreement between the parallel readers for both the iPAT imaging and the conventional technique, respectively, as well as between imaging techniques was found encouraging with inter-observer kappa values ranging between 0.78 and 0.98 for both imaging techniques, and the inter-method kappa values ranging between 0.88 and 1.00 for both clinical readers. All pathological findings (e.g. occult fractures, meniscal and cruciate ligament tears, torn and interpositioned Hoffa's cleft, cartilage damage) were detected by both techniques with comparable performance. The use of iPAT lead to a 48% reduction of acquisition time compared with standard technique. Parallel imaging using mSENSE proved to be an efficient and economic tool for fast musculoskeletal MR imaging of the knee joint with comparable diagnostic performance to conventional MR imaging.
机译:评估了在膝关节创伤性和退行性疾病中使用多个接收器线圈元件和集成并行成像技术(iPAT)的磁共振(MR)成像策略的性能,并将该技术与标准MR成像协议进行了比较。 90名怀疑膝关节内部错乱的患者在1.5 T下接受了MR成像。为了进行信号检测,使用了6通道阵列线圈。所有患者均通过在三个成像平面上由不同涡轮旋转回波序列质子密度(PD),T2加权涡轮旋转回波(TSE)构成的标准成像协议进行了研究,该序列具有和不具有抑制脂肪的功能。使用改进的灵敏度编码(mSENSE)算法,使用加速因子为2的集成并行采集技术(iPAT),重复所有序列。两位放射科医生就整体图像质量,伪像和病理结果独立评估和评分了所有图像。阅读器和成像技术之间的平行评级分别通过成对的kappa系数进行评估,该系数按评估区域进行分层。发现并行阅读器之间分别适用于iPAT成像和常规技术,以及成像技术之间的一致性令人鼓舞,两种成像技术的观察者间kappa值介于0.78至0.98之间,方法间kappa值范围介于2.58和0.58之间。对于两个临床读者而言,介于0.88和1.00之间。两种技术均能检测出所有病理结果(例如隐匿性骨折,半月板和十字韧带撕裂,霍法氏裂和间质撕裂和软骨损伤,软骨损伤),并且具有可比的性能。与标准技术相比,使用iPAT可使采集时间减少48%。使用mSENSE的并行成像被证明是一种高效,经济的工具,可对膝关节进行快速肌肉骨骼MR成像,其诊断性能可与传统MR成像相媲美。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号