The purpose of our study was to evaluate reliability of left ventricular (LV) function and mass quantification in cardiac DSCT exams comparing manual contour tracing and a region-growing-based semiautomatic segmentation analysis software. Thirty-three consecutive patients who underwent cardiac DSCT exams were included. Axial 1-mm slices were used for the semiautomated technique, and short-axis 8-mm slice thickness multiphase image reconstructions were the basis for manual contour tracing. Left ventricular volumes, ejection fraction and myocardial mass were assessed by both segmentation methods. Length of time needed for both techniques was also recorded. Left ventricular functional parameters derived from semiautomatic contour detection algorithm were not statistically different from manual tracing and showed an excellent correlation (p<0.001). The semiautomatic contour detection algorithm overestimated LV mass (180.30+/-44.74 g) compared with manual contour tracing (156.07+/-46.29 g) (p<0.001). This software allowed a significant reduction of the time needed for global LV assessment (mean 174.16+/-71.53 s, p<0.001). Objective quantification of LV function using the evaluated region-growing-based semiautomatic segmentation analysis software is feasible, accurate, reliable and time-effective. However, further improvements are needed to equal results achieved by manual contour tracing, especially with regard to LV mass quantification.
机译:我们的研究目的是在心脏DSCT检查中评估左心室(LV)功能的可靠性和质量定量,比较手动轮廓追踪和基于区域增长的半自动分割分析软件。包括33例接受心脏DSCT检查的连续患者。轴向1毫米切片用于半自动技术,短轴8毫米切片厚度多相图像重建是手动轮廓跟踪的基础。通过两种分割方法评估左心室容积,射血分数和心肌质量。还记录了两种技术所需的时间长度。从半自动轮廓检测算法得出的左心室功能参数与手动追踪没有统计学差异,并显示出极好的相关性(p <0.001)。与手动轮廓跟踪(156.07 +/- 46.29 g)相比,半自动轮廓检测算法高估了LV质量(180.30 +/- 44.74 g)(p <0.001)。该软件可以显着减少总体LV评估所需的时间(平均174.16 +/- 71.53 s,p <0.001)。使用评估的基于区域增长的半自动分割分析软件对LV功能进行客观量化是可行,准确,可靠且省时的。但是,还需要进一步改进,以使通过手动轮廓跟踪获得的结果相等,尤其是在LV质量定量方面。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号