Impact of breast mass size on accuracy of ultrasound elastography vs. conventional B-mode ultrasound: a meta-analysis of individual participants.

机译:乳腺肿块大小对超声弹性成像与常规B型超声准确性的影响:对单个参与者的荟萃分析。

获取原文
获取原文并翻译 | 示例
           

摘要

To conduct an individual patient data meta-analysis comparing the diagnostic performance of ultrasound elastography (USE) versus B-mode ultrasound (USB) across size ranges of breast masses.An extensive literature search of PubMed and other medical/general purpose databases from inception through August 2011 was conducted. Corresponding authors of published studies that reported a direct comparison of the diagnostic performance of USE using the elasticity score versus USB for characterisation of focal breast masses were contacted for their original patient-level data set. Summary diagnostic performance measures were compared for each test within and across three mass size groups (<10 mm, 10-19 mm, and >19 mm).The patient-level data sets were received from five studies, providing information on 1,412 breast masses. For breast masses <10 mm (n?=?543; 121 malignant), the sensitivity/specificity of USE and USB were 76 %/93 % and 95 %/68 %, respectively. For masses 10-19 mm of size (n?=?528; 247 malignant), sensitivity/specificity of USE and USB were 82 %/90 % and 95 %/67 %, respectively. For masses >19 mm of size (n?=?325; 162 malignant), sensitivity/specificity of USE and USB were 74 %/94 % and 97 %/55 %, respectively.Regardless of the mass size, USE has higher specificity and lower sensitivity compared to USB in characterising breast masses. The performance of each of these two tests does not vary significantly by mass size.
机译:为了进行单个患者数据的荟萃分析,比较超声弹性成像(USE)与B型超声(USB)在整个乳腺肿块大小范围内的诊断性能。从开始到开始,广泛研究PubMed和其他医学/通用数据库进行了2011年8月。报道发表研究的通讯作者联系了他们,他们使用弹性评分与USB来直接比较USE的诊断性能以表征局灶性乳腺肿块,以获取其原始患者水平的数据集。比较了三个质量尺寸组(<10 mm,10-19 mm和> 19 mm)内和之间的每个测试的简要诊断性能指标。从五项研究中获得了患者水平的数据集,提供了1,412个乳房肿块的信息。对于<10 mm的乳腺肿块(n?=?543; 121恶性),USE和USB的敏感性/特异性分别为76%/ 93%和95%/ 68%。对于大小为10-19mm的肿块(n≥528; 247恶性),USE和USB的敏感性/特异性分别为82%/ 90%和95%/ 67%。对于大于19毫米大小的肿块(n?=?325; 162恶性),USE和USB的敏感性/特异性分别为74%/ 94%和97%/ 55%。与USB相比,在表征乳腺肿块方面灵敏度较低。这两个测试中每个测试的性能在质量尺寸上均无明显变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号