首页> 外文期刊>European radiology >64-Slice CT angiography of the abdominal aorta and abdominal arteries: comparison of the diagnostic efficacy of iobitridol 350 mgI/ml versus iomeprol 400 mgI/ml in a prospective, randomised, double-blind multi-centre trial.
【24h】

64-Slice CT angiography of the abdominal aorta and abdominal arteries: comparison of the diagnostic efficacy of iobitridol 350 mgI/ml versus iomeprol 400 mgI/ml in a prospective, randomised, double-blind multi-centre trial.

机译:腹主动脉和腹腔动脉的64层CT血管造影:在一项前瞻性,随机,双盲多中心试验中,碘苯吡啶醇350 mgI / ml与碘美普尔400 mgI / ml的诊断功效比较。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: The purpose of this study was to assess the influence of iodine concentration on diagnostic efficacy in multi-detector-row computed tomography (MDCT) angiography of the abdominal aorta and abdominal arteries. METHODS: IRB approval and informed consent were obtained. In this double-blind trial, patients were randomised to undergo MDCT angiography of the abdominal arteries during administration of iobitridol (350 mgI/ml) or iomeprol (400 mgI/ml). Each centre applied its own technique for delivery of contrast medium, regardless of iodine concentration. Diagnostic efficacy, image quality, visualisation of the arterial wall and arterial enhancement were evaluated. A total of 153 patients received iobitridol and 154 received iomeprol. RESULTS: The ability to reach a diagnosis was "satisfactory" to "totally satisfactory" in 152 (99.3%) and 153 (99.4%) patients respectively. Image quality was rated as being "good" to "excellent" in 94.7 and 94.8% segments respectively. Similar results were observed for image quality of arterial walls (84.3 vs. 83.2%). The mean relative changes in arterial enhancement between baseline and arterial phase images showed no statistically significant differences. CONCLUSION: This study demonstrated the non-inferiority of the 350 versus 400 mgI/ml iodine concentration, in terms of diagnostic efficacy, in abdominal MDCT angiography. It also confirmed the high robustness and reliability of this technique across multi-national practices.
机译:目的:本研究的目的是评估碘浓度对腹主动脉和腹动脉的多排行计算机断层扫描(MDCT)血管造影术中诊断功效的影响。方法:获得IRB的批准和知情同意。在这项双盲试验中,患者在服用碘比妥醇(350 mgI / ml)或艾美普尔(400 mgI / ml)的过程中随机接受腹部动脉的MDCT血管造影。每个中心都采用自己的技术来输送造影剂,而与碘浓度无关。评估了诊断功效,图像质量,动脉壁的可视化和动脉增强。共有153例患者接受了iobitridol,154例接受了iomeprol。结果:分别有152名患者(99.3%)和153名患者(99.4%)的诊断能力“令人满意”至“完全令人满意”。图像质量分别在94.7和94.8%的部分中被评为“好”至“优秀”。动脉壁的图像质量观察到相似的结果(84.3对83.2%)。基线和动脉相位图像之间的动脉增强平均相对变化显示无统计学显着差异。结论:本研究证明在腹部MDCT血管造影中,在诊断功效方面,碘浓度分别为350 mg / ml和400 mgI / ml较差。它还证实了该技术在跨国实践中具有很高的鲁棒性和可靠性。

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号