首页> 外文期刊>European radiology >High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus.
【24h】

High resolution MR imaging of the fetal heart with cardiac triggering: a feasibility study in the sheep fetus.

机译:心脏触发对胎儿心脏的高分辨率MR成像:在绵羊胎儿中的可行性研究。

获取原文
获取原文并翻译 | 示例
           

摘要

The aim of this study was to perform fetal cardiac magnetic resonance imaging (MRI) with triggering of the fetal heart beat in utero in a sheep model. All experimental protocols were reviewed and the usage of ewes and fetuses was approved by the local animal protection authorities. Images of the hearts of six pregnant ewes were obtained by using a 1.5-T MR system (Philips Medical Systems, Best, Netherlands). The fetuses were chronically instrumented with a carotid catheter to measure the fetal heart frequency for the cardiac triggering. Pulse wave triggered, breath-hold cine-MRI with steady-state free precession (SSFP) was achieved in short axis, two-, four- and three-chamber views. The left ventricular volume and thus the function were measured from the short axis. The fetal heart frequencies ranged between 130 and 160 bpm. The mitral, tricuspid, aortic, and pulmonary valves could be clearly observed. The foramen ovale could be visualized. Myocardial contraction was shown in cine sequences. The average blood volume at the end systole was 3.4 + or - 0.2 ml (+ or - SD). The average volume at end diastole was 5.2 + or - 0.2 ml; thus the stroke volumes of the left ventricle in the systole were between 1.7 and 1.9 ml with ejection fractions of 38.6% and 39%, respectively. The pulse wave triggered cardiac MRI of the fetal heart allowed evaluation of anatomical structures and functional information. This feasibility study demonstrates the applicability of MRI for future evaluation of fetuses with complex congenital heart defects, once a noninvasive method has been developed to perform fetal cardiac triggering.
机译:这项研究的目的是在绵羊模型中通过触发子宫内胎儿心跳来执行胎儿心脏磁共振成像(MRI)。审查了所有实验方案,母羊和胎儿的使用已获当地动物保护当局批准。通过使用1.5-T MR系统(Philips Medical Systems,Best,荷兰)获得了六只怀孕母羊的心脏图像。使用颈动脉导管对胎儿进行长期检测,以测量胎儿心脏的频率以触发心脏。在短轴,二腔,四腔和三腔视图中实现了具有稳态自由进动(SSFP)的脉搏波触发式屏气电影MRI。从短轴测量左心室容积并因此测量功能。胎儿的心脏频率介于130和160 bpm之间。可以清楚地观察到二尖瓣,三尖瓣,主动脉和肺动脉瓣。卵圆孔可以看到。在电影序列中显示出心肌收缩。收缩末期的平均血容量为3.4 +或-0.2 ml(+或-SD)。舒张末期的平均体积为5.2 +或-0.2 ml;因此,收缩期左心室的搏动量在1.7和1.9 ml之间,射血分数分别为38.6%和39%。脉冲波触发的胎儿心脏心脏MRI可以评估解剖结构和功能信息。一旦开发出一种非侵入性方法来进行胎儿心脏触发,这项可行性研究证明了MRI在具有复杂先天性心脏缺陷的胎儿的未来评估中的适用性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号