The objective of this study was to compare a newly developed fat-saturated intermediate-weighted (IM-w) 3D fast spin-echo (FSE) sequence with standard 2D IM-w FSE sequences regarding image quality and diagnostic performance in assessing abnormal findings of the knee. MR imaging was performed at 3.0 T in 50 patients. Images were assessed independently by three radiologists. Image quality was rated significantly higher (p < 0.05) for the 2D versus the 3D FSE sequences. Sensitivity for cartilage lesions was slightly higher for the 3D sequence, but specificity was lower. Low contrast objects were better visualized with 2D sequences, while high contrast objects were better shown with the 3D sequence. Confidence scores were higher for 2D than for 3D sequences, but differences were not significant. In conclusion, isotropic 3D FSE IM-w imaging may enhance standard knee MRI by increased visualization of high contrast lesions; however, 3D FSE image quality was lower.
机译:这项研究的目的是比较新开发的脂肪饱和中间加权(IM-w)3D快速自旋回波(FSE)序列与标准2D IM-w FSE序列在评估图像异常发现方面的图像质量和诊断性能膝盖。 50例患者在3.0 T时进行了MR成像。图像由三位放射科医生独立评估。与3D FSE序列相比,2D的图像质量等级明显更高(p <0.05)。对于3D序列,软骨损伤的敏感性稍高,但特异性较低。使用2D序列可以更好地显示低对比度对象,而使用3D序列可以更好地显示高对比度对象。 2D的置信度得分高于3D序列,但差异不明显。总之,各向同性3D FSE IM-w成像可通过增加高对比度病变的可视化来增强标准的膝关节MRI。但是,3D FSE图像质量较低。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号