首页> 外文期刊>European spine journal: official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society >The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis.
【24h】

The effect of the X-Stop implantation on intervertebral foramen, segmental spinal canal length and disc space in elderly patients with lumbar spinal stenosis.

机译:X-Stop植入对老年腰椎管狭窄症患者的椎间孔,节段性椎管长度和椎间盘间隙的影响。

获取原文
获取原文并翻译 | 示例
           

摘要

To evaluate the biomechanical effect of the X-Stop device on the intervertebral foramen (IVF) and segmental spinal canal length (SSCL), as well as the intervertebral disc space at the implanted and the adjacent segments in patients with lumbar spinal stenosis (LSS).Eight elderly patients with LSS, scheduled for X-stop implantation, were CT or MRI scanned to construct 3D vertebral models (L2-S1). Before and after the surgery, each patient was also imaged using a dual-fluoroscopic image system during weight-bearing standing and maximum extension-flexion. The positions of the vertebrae were then determined using an established 2D-3D model matching method.The data revealed that the postoperative IVF area was significantly increased by 32.9% (or 32 mm2) (p<0.05) and the IVF width was increased by 24.4% (or 1.1 mm, p=0.06) during extension, but with minimal change in standing and flexion. The IVF heights were significantly (p<0.05) increased at standing by 1.2 mm and extension by 1.8 mm, but not at flexion. The SSCL were significantly (p<0.05) increased at extension by 1.2 mm, but not at standing and flexion. Anterior disc space of the implanted level was significantly decreased from 8.0 to 6.6 mm during standing.The X-Stop implantation efficiently enlarged the IVF area in the elderly patients with LSS at the operated level with little biomechanical effect immediately on the superior and inferior adjacent levels. However, it reduced the anterior disc space at the implanted level.
机译:评估X-Stop设备对腰椎管狭窄症(LSS)患者的椎间孔(IVF)和节段性椎管长度(SSCL)以及植入的椎间盘间隙和相邻节段的椎间盘间隙的生物力学作用对计划进行X停止植入的8例LSS老年患者进行CT或MRI扫描,以构建3D椎骨模型(L2-S1)。手术前后,在负重站立和最大伸展屈曲期间,还使用双透视成像系统对每个患者进行成像。然后使用建立的2D-3D模型匹配方法确定椎骨位置。数据显示,术后IVF面积显着增加了32.9%(或32 mm2)(p <0.05),IVF宽度增加了24.4伸展过程中的重量百分比(或1.1毫米,p = 0.06),但站立和屈曲变化很小。站立时1.2 mm和伸展时1.8 mm,IVF高度显着增加(p <0.05),但屈曲时IVF高度则没有。伸展1.2 mm时,SSCL显着增加(p <0.05),但站立和屈曲时则没有。站立时前椎间盘间隙从8.0 mm显着减少到6.6 mm.X-Stop植入在手术水平下有效地扩大了LSS老年患者的IVF面积,对上,下相邻水平的生物力学影响不大。然而,它在植入水平减少了前椎间盘间隙。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号