首页> 外文期刊>European journal of echocardiography: the journal of the Working Group on Echocardiography of the European Society of Cardiology >Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects
【24h】

Concordance between M-mode, pulsed Tissue Doppler, and colour Tissue Doppler in the assessment of mitral annulus systolic excursion in normal subjects

机译:M型,脉冲组织多普勒和彩色组织多普勒在正常人二尖瓣环收缩偏移评估中的一致性

获取原文
获取原文并翻译 | 示例
           

摘要

Aims: M-mode left atrioventricular plane displacement (AVPD) correlates with Tissue Doppler (TD) peak systolic annular velocity in healthy individuals. This approach is biased by several interacting factors related to the structural complexity of mitral annulus physiology, including the different dimensional values of measures, the confounding effect of isovolumic motions, and the spectral thickness of pulsed TD envelope. We sought to analyze the effective concordance between techniques in the assessment of systolic annular excursion. Methods and results: In 92 healthy subjects (age 60.5 ± 18.6, 43.5% women), systolic AVPD was measured after exclusion of isovolumic components using three techniques: (i) M-mode; (ii) temporal integration of pulsed TD systolic wave; and (iii) colour TD-derived tissue tracking. Close correlations of M-mode AVPD with pulsed TD velocity-time integral (VTI) (R = 0.90, P < 0.0001) and colour TD AVPD (R = 0.86, P < 0.0001) were found. However, M-mode AVPD underestimated pulsed TD VTI (mean error -5.1 ± 1.7 mm) and overestimated colour TD AVPD (mean error 3.4 ± 1.3 mm). The concordance between M-mode and pulsed TD increased after adjustment for spectral dispersion of pulsed TD istantaneous velocities (mean error 0.1 ± 1.1 mm). Conclusion: Despite strict correlations exist between M-mode and TD in the assessment of mitral annulus systolic excursion, the effective concordance between techniques is sub-optimal.
机译:目的:M型左房室平面位移(AVPD)与健康个体的组织多普勒(TD)收缩期峰值环形速度相关。这种方法受到与二尖瓣环生理结构复杂性相关的几个相互作用因素的偏见,包括不同尺寸的测量值,等容运动的混杂效应以及脉冲TD包络的频谱厚度。我们试图分析评估收缩期环形偏移的技术之间的有效一致性。方法和结果:在92名健康受试者(年龄为60.5±18.6,女性为43.5%)中,使用三种技术在排除等容成分后测量了收缩期AVPD:(i)M型; (ii)脉冲TD收缩波的时间积分; (iii)彩色TD来源的组织跟踪。发现M模式AVPD与脉冲TD速度-时间积分(VTI)(R = 0.90,P <0.0001)和彩色TD AVPD(R = 0.86,P <0.0001)密切相关。但是,M模式AVPD低估了脉冲TD VTI(平均误差-5.1±1.7毫米),而高估了彩色TD AVPD(平均误差3.4±1.3毫米)。调整脉冲TD瞬时速度的频谱色散(平均误差0.1±1.1 mm)后,​​M模式和脉冲TD的一致性增加。结论:尽管在评估二尖瓣环收缩偏移时M模式和TD之间存在严格的相关性,但技术之间的有效一致性并不理想。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号