首页> 外文期刊>European journal of echocardiography: the journal of the Working Group on Echocardiography of the European Society of Cardiology >Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography.
【24h】

Prediction of the annuloplasty ring size in patients undergoing mitral valve repair using real-time three-dimensional transoesophageal echocardiography.

机译:使用实时三维经食道超声心动图预测二尖瓣修复患者瓣环成形术环的大小。

获取原文
获取原文并翻译 | 示例
       

摘要

AIMS: We sought to investigate the additional value of real-time three-dimensional transoesophageal echocardiography (RT 3D TOE)-guided sizing for predicting annuloplasty ring size during mitral valve repair. METHODS AND RESULTS: In 53 patients undergoing elective mitral valve repair, an RT 3D TOE was performed pre- and post-operatively. The digitally stored loops were imported into a software for mitral valve assessment. The annuloplasty ring size was predicted by superimposing computer-aided design (CAD) models of annuloplasty rings onto Live 3D zoom loops, measurement of the intercommissural distance, or the height of the anterior mitral leaflet. The surgeon implanted the annuloplasty ring according to the usual surgical technique and was blinded to the echocardiographic measurement results. Pre-operative correlation between the selected ring size with mitral valve assessment and the actual implanted annuloplasty ring size was 0.91. The correlation for measurement of the intercommissural distance was 0.55 and for measurement of the height of the anterior mitral leaflet 0.75. The post-operative correlation with the actual implanted ring size was 0.96 for mitral valve assessment, 0.92 for intercommissural distance, and 0.79 for the anterior mitral leaflet height. CONCLUSION: Superimposition of annuloplasty ring CAD models on the Live 3D zoom loops of the mitral valve using mitral valve assessment is superior to two-dimensional measurements of the intercommissural distance or the height of the anterior mitral leaflet in predicting correct annuloplasty ring size.
机译:目的:我们试图研究实时三维经食道超声心动图(RT 3D TOE)引导的尺寸在二尖瓣修复过程中预测瓣环成形术环大小的附加价值。方法和结果:53例接受选择性二尖瓣修复的患者在手术前后进行了RT 3D TOE。将数字存储的回路导入到用于二尖瓣评估的软件中。通过将瓣环成形术环的计算机辅助设计(CAD)模型叠加到Live 3D缩放环上,测量合缝间距离或二尖瓣前叶的高度来预测瓣环成形术环的大小。外科医生根据常规手术技术植入了瓣环成形术环,并且对超声心动图测量结果不知情。所选二尖瓣评估环尺寸与实际植入瓣环成形术环尺寸的术前相关性为0.91。术中距离的相关性为0.55,二尖瓣前叶高度的相关性为0.75。二尖瓣评估与实际植入环尺寸的术后相关性为二尖瓣评估为0.96,合缝间距离为0.92,二尖瓣前叶高度为0.79。结论:使用二尖瓣评估将瓣环成形术环CAD模型叠加在二尖瓣的Live 3D缩放环上,在预测正确的瓣环成形术环的大小方面,优于二尖瓣间距离或前二尖瓣小叶高度的二维测量。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号