This study was designed in order to compare the strain and strain rate deformation parameters assessed by speckle tracking imaging (STI) with those of tissue Doppler imaging (TDI) and conductance catheter measurements in chronic murine models of left ventricular (LV) dysfunction.Twenty-four male C57BL/6J mice were assigned to wild-type (n = 8), myocardial infarction (n = 8) and transaortic constriction (n = 8) groups. Echocardiographic and conductance measurements were simultaneously performed at rest and during dobutamine infusion (5 μg/kg/min) in all animals 10 weeks post-surgery. The LV circumferential strain (Scirc) and the strain rate (SRcirc) were derived from grey scale and tissue Doppler data at frame rates of 224 and 375 Hz, respectively. Scirc and SRcirc by TDI/STI correlated well with the preload recruitable stroke work (PRSW) (r = -0.64 and -0.71 for TDI; r = -0.46 and -0.50 for STI, P < 0.05). Both modalities showed a good agreement with respect to Scirc and SRcirc (r = 0.60 and r = 0.63, P < 0.05). During stress, however, TDI-estimated?Scirc and SRcirc values were predominantly higher than those measured by STI (P < 0.05). The similarity of Scirc and SRcirc measurements with respect to the STI/TDI data was examined by the Bland-Altman analysis.In mice, the STI- and TDI-derived strain and strain rate deformation parameters relate closely to intrinsic myocardial function. At low heart rate-to-frame rate ratios (HR/FR), both STI and TDI are equally acceptable for assessing the LV function non-invasively in these animals. At HR/FR (e.g. dobutamine challenge), however, these methods cannot be used interchangeably as STI underestimates S and SR at high values.
机译:本研究旨在比较散斑追踪成像(STI),组织多普勒成像(TDI)和电导导管测量在左心室(LV)功能障碍的慢性鼠模型中评估的应变和应变率变形参数。将四只雄性C57BL / 6J小鼠分为野生型(n = 8),心肌梗塞(n = 8)和经主动脉缩窄(n = 8)组。手术后10周在所有动物的休息和多巴酚丁胺输注期间(5μg/ kg / min)同时进行超声心动图和电导率测量。左室周向应变(Scirc)和应变率(SRcirc)分别来自灰度和组织多普勒数据,帧频分别为224和375 Hz。 TDI / STI的Scirc和SRcirc与预负荷可招募卒中功(PRSW)密切相关(TDI的r = -0.64和-0.71; STI的r = -0.46和-0.50,P <0.05)。两种模式均显示出关于Scirc和SRcirc的良好一致性(r = 0.60和r = 0.63,P <0.05)。然而,在压力下,TDI估计的Scirc和SRcirc值主要高于STI测得的值(P <0.05)。通过Bland-Altman分析检查了Scirc和SRcirc测量值与STI / TDI数据的相似性。在小鼠中,源自STI和TDI的应变和应变率变形参数与固有心肌功能密切相关。在低心率/帧率比率(HR / FR)下,STI和TDI均可接受以无创方式评估这些动物的LV功能。但是,在HR / FR(例如多巴酚丁胺挑战)下,这些方法不能互换使用,因为STI低估了S和SR的高值。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号