...
首页> 外文期刊>European Journal of Radiology >Comparison of acquired diffusion weighted imaging and computed diffusion weighted imaging for detection of hepatic metastases
【24h】

Comparison of acquired diffusion weighted imaging and computed diffusion weighted imaging for detection of hepatic metastases

机译:采集的扩散加权成像和计算机扩散加权成像在肝转移检测中的比较

获取原文
获取原文并翻译 | 示例

摘要

Objective: To compare the accuracy of acquired diffusion weighted imaging (DWI) (b = 1000 s/mm2) with that of computed DWI (b = 1000 s/mm 2) for the detection of hepatic metastases. Methods: Two hundred and sixty patients underwent abdominal magnetic resonance imaging (MRI) at 3.0 T for the evaluation of hepatic metastasis, including T1-weighted imaging (T1WI), T2-weighted imaging (T2WI), heavily T2WI, DWI with b-values of 0, 500, 1000 s/mm2, and three-dimensional dynamic contrast-enhanced MRI with gadolinium-ethoxybenzyl-diethylenetriamine pentaacetic acid (Gd-EOB-DTPA), and 190 patients were included in the final study. Computed DWI (=1000 s/mm 2) was synthesized from lower b-values (b = 0 and 500 s/mm 2). Two groups were assigned and compared: group A (acquired DWI) and group B (computed DWI). Diagnostic performance using each imaging set was evaluated by receiver operating characteristic (ROC) curve analysis. Results: A total of 76 hepatic metastases were confirmed. The area under the ROC curve (Az) of group A was larger than that of group B (Observer 1; 0.919-0.915, Observer 2; 0.926-0.901), but there were no significant differences (observer 1, P = 0.500; observer 2, P = 0.190). There were 5 metastases visualized in group A, but these were difficult to detect in group B. However, there were 2 metastases that were better visualized in group B than in group A. Conclusion: There were no significant differences between acquired DWI and computed DWI in the detection of hepatic metastasis. ? 2012 Elsevier Ireland Ltd.
机译:目的:比较获得性弥散加权成像(DWI)(b = 1000 s / mm2)与计算得出的DWI(b = 1000 s / mm 2)的准确性,以检测肝转移。方法:260例患者在3.0 T时接受腹部磁共振成像(MRI)评估肝转移,包括T1加权成像(T1WI),T2加权成像(T2WI),重度T2WI,具有b值的DWI分别在0、500、1000 s / mm2的条件下进行三维动态对比增强MRI,并使用g乙氧基苄基-二亚乙基三胺五乙酸(Gd-EOB-DTPA),最终研究包括190名患者。从较低的b值(b = 0和500 s / mm 2)合成了计算的DWI(= 1000 s / mm 2)。分为两组并进行比较:A组(获得的DWI)和B组(计算的DWI)。通过接收器工作特性(ROC)曲线分析评估使用每个成像组的诊断性能。结果:总共确认了76例肝转移。 A组的ROC曲线下面积(Az)大于B组(观察者1; 0.919-0.915,观察者2; 0.926-0.901),但无显着差异(观察者1,P = 0.500;观察者2,P = 0.190)。 A组中有5个转移灶可见,但B组中很难发现。但是B组中有2个转移灶比A组更好。结论:获得性DWI与计算机DWI之间无显着差异在检测肝转移中。 ? 2012爱思唯尔爱尔兰有限公司

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号