...
首页> 外文期刊>European Journal of Radiology >Whole tumour quantitative measurement of first-pass perfusion of oesophageal squamous cell carcinoma using 64-row multidetector computed tomography: correlation with microvessel density.
【24h】

Whole tumour quantitative measurement of first-pass perfusion of oesophageal squamous cell carcinoma using 64-row multidetector computed tomography: correlation with microvessel density.

机译:使用64行多探测器计算机断层扫描对食道鳞状细胞癌首过灌注进行全肿瘤定量测量:与微血管密度的相关性。

获取原文
获取原文并翻译 | 示例
           

摘要

PURPOSE: To assess correlations between whole tumour first-pass perfusion parameters obtained with 64-row multidetector computed tomography (MDCT), and microvessel density (MVD) in oesophageal squamous cell carcinoma. MATERIALS AND METHODS: Thirty-one consecutive patients with surgically confirmed oesophageal squamous cell carcinomas were enrolled into our study. All the patients underwent whole tumour first-pass perfusion scan with 64-row MDCT. Perfusion parameters, including perfusion (PF), peak enhanced density (PED), blood volume (BV), and time to peak (TTP) were measured using Philips perfusion software. Postoperative tumour specimens were assessed for MVD. Pearson correlation coefficient tests were performed to determine correlations between each perfusion parameter and MVD. RESULTS: Mean values for PF, PED, BV and TTP of the whole tumour were 28.85 +/- 20.29 ml/min/ml, 23.16 +/- 8.09 HU, 12.13 +/- 5.21 ml/100g, and 35.05 +/- 13.85 s, respectively. Mean MVD in whole tumour at magnification (x200) was 15.75 +/- 4.34 microvessel/tumour sample (vessels/0.723 mm(2)). PED and BV were correlated with MVD (r=0.651 and r=0.977, respectively, all p<0.05). However, PF and TTP were not correlated with MVD (r=0.070 and r=0.100, respectively, all p>0.05). CONCLUSION: The BV value of first-pass perfusion CT could reflect MVD in oesophageal squamous cell carcinoma, and can be an indicator for evaluating the tumour angiogenesis.
机译:目的:评估64行多排计算机断层扫描(MDCT)获得的整个肿瘤首过灌注参数与食管鳞状细胞癌中的微血管密度(MVD)之间的相关性。材料与方法:31例经手术确诊的食管鳞状细胞癌患者被纳入本研究。所有患者均接受了64行MDCT的全肿瘤首过灌注扫描。使用Philips灌注软件测量灌注参数,包括灌注(PF),峰增强密度(PED),血容量(BV)和达到峰值时间(TTP)。评估术后肿瘤标本的MVD。进行Pearson相关系数测试以确定每个灌注参数和MVD之间的相关性。结果:整个肿瘤的PF,PED,BV和TTP平均值分别为28.85 +/- 20.29 ml / min / ml,23.16 +/- 8.09 HU,12.13 +/- 5.21 ml / 100g和35.05 +/- 13.85分别。整个肿瘤在放大倍数(x200)下的平均MVD为15.75 +/- 4.34微血管/肿瘤样品(血管/0.723 mm(2))。 PED和BV与MVD相关(r分别为r = 0.651和r = 0.977,所有p <0.05)。然而,PF和TTP与MVD不相关(r = 0.070和r = 0.100,均p> 0.05)。结论:初次灌注CT的BV值可反映食管鳞状细胞癌的MVD,可作为评价肿瘤血管生成的指标。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号