Purpose: To evaluate the influence of different saline chaser volumes and different saline chaser flow rates on the intravascular contrast enhancement in MDCT. Materials and methods: In a physiological flow phantom contrast medium (120 ml, 300mgI/ml, Ultravist 300) was administered at a flow rate of 6 ml/s followed by different saline chaser volumes (0,30,60 and 90 ml) at the same injection rate or followed by a 30-ml saline chaser at different injection rates (2,4, 6 and 8 ml/s). Serial CT-scans at a level covering the pulmonary artery, the ascending and the descending aorta replica were obtained. Time-enhancement curves were computed and both pulmonary and aortic peak enhancement and peak time were determined. Results: Compared to contrast medium injection without a saline chaser the pushing with a saline chaser (30, 60, and 90 ml) resulted in a statistically significant increased pulmonary peak enhancement (all p = 0.008) and prolonged peak time (p = 0.032, p = 0.024 and p = 0.008, respectively). Highest aortic peak enhancement values were detected for a saline chaser volume of 30 ml. A saline chaser flow rate of 8 ml/s resulted in the highest pulmonary peak enhancement values compared to flow rates of 2, 4 and 6 ml/s (all p = 0.008). Aortic peak enhancement showed the highest values for a flow rate of 6 ml/s. Conclusion: A saline chaser volume of 30 ml and an injection rate of 6 ml/s are sufficient to best improve vascular contrast enhancement in the pulmonary artery and the aorta in MDCT.
机译:目的:评估不同的盐水追踪器体积和不同的盐水追踪器流速对MDCT中血管内造影剂增强的影响。材料和方法:在生理流幻影造影剂(120 ml,300mgI / ml,Ultravist 300)中,以6 ml / s的流速给药,然后以不同的生理盐水量(0,30,60和90 ml)相同的注射速度,或以不同的注射速度(2、4、6和8 ml / s)跟随30 ml盐水追踪器。在覆盖肺动脉,升主动脉副本和降主动脉副本的水平上进行了连续CT扫描。计算了时间增强曲线,并确定了肺动脉和主动脉的峰值增强和峰值时间。结果:与不使用盐水搅拌器的造影剂注射相比,用盐水搅拌器(30、60和90 ml)推动可导致统计学上显着增加的肺峰增强(所有p = 0.008)和延长的峰时间(p = 0.032, p = 0.024和p = 0.008)。对于30 ml的盐水追踪器,检测到最高的主动脉峰值增强值。与2、4和6 ml / s的流速相比,盐水追踪器的8 ml / s的流速导致最高的肺峰值增强值(所有p = 0.008)。主动脉峰值增强显示最高值为6 ml / s的流速。结论:30 ml的生理盐水追踪器和6 ml / s的注射速率足以最好地改善MDCT中肺动脉和主动脉的血管造影增强效果。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号