...
首页> 外文期刊>Brain & Development >Standard values for the urine HVA/VMA ratio in neonates as a screen for Menkes disease
【24h】

Standard values for the urine HVA/VMA ratio in neonates as a screen for Menkes disease

机译:新生儿尿液HVA / VMA比值的标准值,用于筛查Menkes病

获取原文
获取原文并翻译 | 示例

摘要

Background: Menkes disease is a lethal disorder associated with copper metabolism. Although early treatment with copper-histidine injections can improve outcomes, early diagnosis is difficult because the clinical features of Menkes disease are subtle or do not manifest in affected neonates. Previous report stated that the low activity of dopamine P-hydroxylase, a copper-dependent enzyme, leads to increases in the urine homovanillic acid/vanillylmandelic acid (HVA/VMA) ratios in patients with Menkes disease, and indicated that a urine HVA/VMA ratio cut-off value of >4 is useful in screening for Menkes disease. Methods: We examined the standard values of the urine HVA/VMA ratio in unaffected neonates and assessed its use as a screening parameter for Menkes disease among neonates. In total, 112 neonates, aged between 1 and 6 days, were enrolled in the study and were classified into 2 groups based on their urine HVA/VMA ratios: high (>4) and low (<= 4). Results: Multivariate logistic analysis revealed that mechanical ventilation was an independent risk factor for a high urine HVA/VMA ratio (odds ratio: 21.94; 95% confidence interval: 2.82-247.03; p = 0.004). The mean urine HVA/VMA ratio was 2.47 +/- 0.67 among 92 neonates who did not receive mechanical ventilation. Conclusion: This study established standard values for the urine HVA/VMA ratio in newborn babies that could be useful in screening for Menkes disease among neonates. (C) 2014 The Japanese Society of Child Neurology. Published by Elsevier B.V. All rights reserved.
机译:背景:Menkes病是与铜代谢有关的致死性疾病。尽管早期用铜-组氨酸注射液治疗可以改善预后,但由于Menkes病的临床特征微妙或在受影响的新生儿中没有表现出来,因此早期诊断很困难。先前的报告指出,多巴胺P-羟化酶(一种铜依赖性酶)的低活性导致Menkes病患者的尿高香草酸/香草锰酸(HVA / VMA)比率增加,并指出尿HVA / VMA比率截止值> 4可用于筛查Menkes疾病。方法:我们检查了未患病新生儿的尿液HVA / VMA比值的标准值,并评估了其作为Menkes病筛查指标的用途。总共有112名年龄在1至6天之间的新生儿参加了研究,并根据其尿液HVA / VMA比分为高(> 4)和低(<= 4)两组。结果:多元逻辑分析表明,机械通气是尿HVA / VMA高比率的独立危险因素(奇数比率:21.94; 95%置信区间:2.82-247.03; p = 0.004)。 92例未接受机械通气的新生儿的平均尿液HVA / VMA比为2.47 +/- 0.67。结论:本研究建立了新生儿尿液HVA / VMA比值的标准值,可用于筛查新生儿Menkes病。 (C)2014年日本儿童神经病学会。由Elsevier B.V.发布。保留所有权利。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号