Presumed pseudobacteremia outbreak resulting from contamination of proportional disinfectant dispenser.

机译:推测是由于比例消毒剂分配器受到污染而导致的假菌血症暴发。

获取原文
获取原文并翻译 | 示例
       

摘要

Reported here are the microbiological and epidemiological details of a presumed outbreak of aerobic gram-negative bacilli infections affecting 19 hematological patients, which was traced to contaminated disinfectant. Over a 5-month period, the following organisms were isolated from the blood cultures of 19 neutropenic patients: Pseudomonas fluorescens (n = 13), Achromobacter xylosoxidans (n = 12), Comamonas testosteroni (n = 2) or Stenotrophomonas maltophilia (n = 1). The affected patients were all treated with an expensive regimen of broad-spectrum antibiotic therapy. The same bacteria were recovered from environmental samples as well as from the water pipes of an apparatus for dispensing disinfectant (didecyldimethylammonium chloride). Genotyping results indicated that many of the clinical strains were identical to strains isolated from the apparatus. It was eventually discovered that the night staff was in the habit of disinfecting the blood-culture bottles before use, thereby contaminating the bottles with bacteria contained in the disinfectant. Contamination of the apparatus resulted from faulty maintenance.
机译:此处报道的是可能影响19例血液病患者的需氧革兰氏阴性细菌感染暴发的微生物学和流行病学详细信息,其追溯至污染的消毒剂。在五个月的时间里,从19名中性粒细胞减少症患者的血液培养物中分离出以下生物:荧光假单胞菌(n = 13),木糖氧化无色杆菌(n = 12),睾丸间夜蛾(n = 2)或嗜麦芽窄食单胞菌(n = 1)。受影响的患者均接受了昂贵的广谱抗生素治疗方案。从环境样品以及分配消毒剂(氯化十二烷基二甲基铵)的设备的水管中回收了相同的细菌。基因分型结果表明,许多临床菌株与从该设备分离的菌株相同。最终发现,夜间工作人员习惯于在使用前对血液培养瓶进行消毒,从而使消毒剂中的细菌污染了培养瓶。维修不当会导致设备污染。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号