The aim of this retrospective study was to evaluate the Immunoquick+4 (BioSynex, Strasbourg, France), a three-band malaria rapid diagnostic test (MRDT) targeting histidine-rich protein-2 (HRP-2) and pan Plasmodium-specific parasite lactate dehydrogenase, in a non-endemic reference setting. Stored whole-blood samples (n = 613) from international travellers suspected of malaria were used, with microscopy corrected by polymerase chain reaction (PCR) as the reference method. Samples infected by P. falciparum (n = 323), P. vivax (n = 97), P. ovale (n = 73) and P. malariae (n = 25) were selected, as well as 95 malaria-negative samples. The overall sensitivities of the Immunoquick+4 for the diagnosis of P. falciparum, P. vivax, P. malariae and P. ovale were 88.9, 75.3, 56.0 and 19.2%, respectively. Sensitivity was significantly related to parasite density for P. falciparum (93.6% versus 71.4% at parasite densities >100/microl and 500/microl and
机译:这项回顾性研究的目的是评估Immunoquick + 4(BioSynex,Strasbourg,France),这是一种针对富含组氨酸的蛋白质2(HRP-2)和泛疟原虫特异性寄生虫的三波段疟疾快速诊断测试(MRDT)。乳酸脱氢酶,在非地方性参考环境中。使用来自怀疑患有疟疾的国际旅行者的全血样本(n = 613),并通过聚合酶链反应(PCR)校正显微镜作为参考方法。选择受恶性疟原虫(n = 323),间日疟原虫(n = 97),卵圆形疟原虫(n = 73)和疟疾疟原虫(n = 25)感染的样本,以及95例疟疾阴性样本。 Immunoquick + 4诊断恶性疟原虫,间日疟原虫,疟原虫和卵形疟原虫的总体敏感性分别为88.9%,75.3%,56.0%和19.2%。敏感性与恶性疟原虫的寄生虫密度显着相关(寄生虫密度> 100 / microl和<或= 100 / microl分别为93.6%和71.4%)和间日疟原虫(寄生虫密度> 500 / p时分别为86.8%和48.3%)。微升和分别小于或等于500 /微升)。 Immunoquick + 4在测试结果和谱线强度方面均显示出良好的可重复性和可靠性。 Immunoquick + 4在恶性疟原虫和间日疟原虫的检测中表现良好。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号