...
首页> 外文期刊>European journal of applied physiology >Breath-by-breath fluctuations of pulmonary gas exchange and ventilation in COPD patients.
【24h】

Breath-by-breath fluctuations of pulmonary gas exchange and ventilation in COPD patients.

机译:COPD患者的呼吸频率随呼吸气体交换和通气而变化。

获取原文
获取原文并翻译 | 示例

摘要

The purpose of the study was to characterise statistically the inherent fluctuations in breath-by-breath measurements of pulmonary gas exchange (oxygen uptake and carbon dioxide output, V*O2 and V*CO2, respectively) and pulmonary ventilation (V*E) in patients with chronic obstructive pulmonary disease (COPD) and to compare them with those of healthy control subjects. Thirty subjects with COPD [mean (SD): 67 (6) years old; forced expiratory volume in 1 min, FEV1 1.25( 0.18) l; 42 (6)% predicted FEV1] and 12 healthy subjects [31 (3) years old; FEV1 3.62 (0.54) l; 99 (8)% predicted FEV1] performed exercise tests on a cycle ergometer at a constant work rate of moderate intensity. Steady-state exercise values for V*O2, V*CO2 and V*E were 905 (96) ml.min(-1), 847(90) ml.min(-1) and 23 (3) l.min(-1), respectively for the COPD patients and 1239(89) ml.min(-1), 1191(84) ml.min(-1)and 37(3) l.min(-1), respectively, for the healthy controls. The breath-by-breath fluctuations were well characterised by a Gaussian density-probability function with breath-to-breath autocorrelations that were not significantly different from 0, up to four subsequent breaths. Its magnitude varied among variables, but was independent of the signal amplitude for the same subject and variable. With ratios of amplitude of fluctuation:signal of around 10%, typical of the patients studied, the resolution of time constants and amplitude were congruent with 9 s and congruent with 100 ml.min(-1), respectively for V*O2 or V*CO2 with one repetition.
机译:这项研究的目的是从统计学上表征肺部气体交换的逐次呼吸测量的固有波动(氧气吸收和二氧化碳输出,分别为V * O2和V * CO2)和肺通气(V * E)。慢性阻塞性肺疾病(COPD)的患者,并将其与健康对照对象进行比较。 30名COPD受试者[平均(SD):67(6)岁; 1分钟内强制呼气量,FEV1 1.25(0.18)l; 42(6)%的预测FEV1]和12位健康受试者[31(3)岁; FEV1 3.62(0.54)l; 99(8)%的预测FEV1]在自行车测功机上以中等强度的恒定工作率进行了运动测试。 V * O2,V * CO2和V * E的稳态运动值为905(96)ml.min(-1),847(90)ml.min(-1)和23(3)l.min( -1)分别适用于COPD患者和1239(89)ml.min(-1),1191(84)ml.min(-1)和37(3)l.min(-1)。健康对照。逐次呼吸波动的特征是高斯密度概率函数,其呼吸与呼吸的自相关性从0到随后的四次呼吸均无显着差异。它的大小在变量之间变化,但是与相同主题和变量的信号幅度无关。 V * O2或V的波动幅度:信号的比率大约为10%(典型值),时间常数和幅度的分辨率分别为9 s和100 ml.min(-1)。 *二氧化碳重复一遍。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号