首页> 外文期刊>European journal of clinical microbiology and infectious diseases: Official publication of the European Society of Clinical Microbiology >Evaluation of the LightCycler SeptiFast test in the rapid etiologic diagnostic of infectious endocarditis.
【24h】

Evaluation of the LightCycler SeptiFast test in the rapid etiologic diagnostic of infectious endocarditis.

机译:对LightCycler SeptiFast测试在传染性心内膜炎的快速病因诊断中的评估。

获取原文
获取原文并翻译 | 示例
           

摘要

The SeptiFast test (Roche Diagnostics) is a new commercial molecular technique that has emerged for the detection of bacteria in blood. We compared in this study the sensitivity of blood culture to a commercially available broad-range real-time polymerase chain reaction (PCR) assay for the detection in blood of 19 bacterial species and six fungal species (SeptiFast test, Roche Diagnostics) in 63 patients with infectious endocarditis (IE). The SeptiFast test is not more sensitive for organisms such as Streptococci, Enterococci, and Staphylococcus aureus (11/29 versus 12/29 for blood culture). It has detected less commonly coagulase-negative Staphylococci (0/15 versus 3/15, P = 0.2) and significantly fewer other microorganisms (0/6 versus 4/6, P = 0.03). However, bacteria were detected from three IE treated by antibiotics, with blood culture negative on admission. The SeptiFast test may be useful in cases of IE in patients treated with antibiotics before admission.
机译:SeptiFast测试(Roche Diagnostics)是一种新兴的商业分子技术,可用于检测血液中的细菌。在这项研究中,我们比较了血液培养对63种患者的19种细菌和6种真菌(SeptiFast测试,Roche Diagnostics)的血液检测对市售的广泛实时聚合酶链反应(PCR)检测的敏感性。感染性心内膜炎(IE)。 SeptiFast测试对诸如链球菌,肠球菌和金黄色葡萄球菌等生物的敏感性更高(血液培养分别为11/29和12/29)。它检测到的凝固酶阴性葡萄球菌较少(0/15对3/15,P = 0.2),而其他微生物则少得多(0/6对4/6,P = 0.03)。但是,从使用抗生素治疗的三个IE中检测到细菌,入院时血培养阴性。对于入院前接受抗生素治疗的IE患者,SeptiFast测试可能有用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号