BACKGROUND AND OBJECTIVE: In this study, we evaluated the ratio of the outer diameter of an uncuffed Mallinckrodt endotracheal tube (ETT, Mallinckrodt Tyco Healthcare UK Ltd) to the MRI-measured internal transverse airway diameter (ITD) at the cricoid level in children. METHODS: With institutional ethics committee approval and parental consent, we measured the ITD at the cricoid level from MRI images of children undergoing MRI diagnostic procedures requiring general anaesthesia with orotracheal intubation. The ITD at the cricoid level was compared with the outer diameter of the utilized ETT. Linear regression analysis was employed to assess the correlation of tracheal diameter with age, height and weight. For all tests, a P value of less than 0.05 was considered to be statistically significant. RESULTS: Fifty patients were studied (21 girls and 29 boys). The difference between the ITD at the cricoid level and the outer tracheal tube diameter ranged from 0.1 to 1.7 mm (median 0.7 mm). The internal transverse tracheal diameters had a strong association with age (r=0.7077, P<0.001), a moderate association with height (r=0.5928, P<0.001), and a mild association with weight (r=0.2437, P<0.001). CONCLUSION: The outer diameter of the 'best-fit' ETT was less than the ITD at the cricoid level by 0.1-1.7 mm. The correlation of the outer diameter of the 'best-fit' ETT with age was stronger than with height or weight.
机译:背景与目的:在这项研究中,我们评估了未充气的Mallinckrodt气管导管(ETT,Mallinckrodt Tyco Healthcare UK Ltd)的外径与儿童在环状环中MRI测量的内部横向气道直径(ITD)的比值。方法:经过机构伦理委员会的批准和父母的同意,我们从需要进行全身麻醉,经口气管插管的MRI诊断儿童的MRI图像中,在环线水平上测量了ITD。将环水平的ITD与使用的ETT的外径进行比较。采用线性回归分析来评估气管直径与年龄,身高和体重的相关性。对于所有测试,P值小于0.05均被视为具有统计学意义。结果:研究了50名患者(21名女孩和29名男孩)。环状环上的ITD与气管外管直径之间的差在0.1到1.7毫米(中值0.7毫米)之间。气管内径与年龄密切相关(r = 0.7077,P <0.001),与身高相关性中等(r = 0.5928,P <0.001),与体重相关性中等(r = 0.2437,P <0.001) )。结论:“最适合” ETT的外径在环线水平处比ITD小0.1-1.7毫米。 “最适合” ETT的外径与年龄的关系比与身高或体重的关系更强。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号