首页> 外文期刊>European Journal of Nuclear Medicine and Molecular Imaging >Proposal for the standardisation of multi-centre trials in nuclear medicine imaging: prerequisites for a European 123I-FP-CIT SPECT database.
【24h】

Proposal for the standardisation of multi-centre trials in nuclear medicine imaging: prerequisites for a European 123I-FP-CIT SPECT database.

机译:关于核医学成像多中心试验标准化的提案:欧洲123I-FP-CIT SPECT数据库的前提条件。

获取原文
获取原文并翻译 | 示例
   

获取外文期刊封面封底 >>

       

摘要

Multi-centre trials are an important part of proving the efficacy of procedures, drugs and interventions. Imaging components in such trials are becoming increasingly common; however, without sufficient control measures the usefulness of these data can be compromised. This paper describes a framework for performing high-quality multi-centre trials with single photon emission computed tomography (SPECT), using a pan-European initiative to acquire a normal control dopamine transporter brain scan database as an example.A framework to produce high-quality and consistent SPECT imaging data was based on three key areas: quality assurance, the imaging protocol and system characterisation. Quality assurance was important to ensure that the quality of the equipment and local techniques was good and consistently high; system characterisation helped understand and where possible match the performance of the systems involved, whereas the imaging protocol was designed to allow a degree of flexibility to best match the characteristics of each imaging device.A total of 24 cameras on 15 sites from 8 different manufacturers were evaluated for inclusion in our multi-centre initiative. All results matched the required level of specification and each had their performance characterised. Differences in performance were found between different system types and cameras of the same type. Imaging protocols for each site were modified to match their individual characteristics to produce comparable high-quality SPECT images.A framework has been designed to produce high-quality data for multi-centre SPECT studies. This framework has been successfully applied to a pan-European initiative to acquire a healthy control dopamine transporter image database.
机译:多中心试验是证明程序,药物和干预措施有效性的重要组成部分。在此类试验中,成像组件变得越来越普遍。但是,如果没有足够的控制措施,这些数据的实用性就会受到损害。本文以泛欧倡议以获取正常对照多巴胺转运蛋白脑扫描数据库为例,介绍了使用单光子发射计算机断层扫描(SPECT)进行高质量多中心试验的框架。质量和一致的SPECT成像数据基于三个关键领域:质量保证,成像协议和系统特性。质量保证对于确保设备和本地技术的质量始终如一是至关重要的;系统特性有助于了解并尽可能匹配相关系统的性能,而成像协议旨在提供一定程度的灵活性,以最佳地匹配每种成像设备的特性。共有来自8个不同制造商的15个站点的24台摄像机评估是否包含在我们的多中心计划中。所有结果均符合规范要求的水平,并且每个结果都有其性能特征。发现不同系统类型和相同类型摄像机之间的性能差异。每个站点的成像协议都经过修改以匹配其各自的特征,以生成可比较的高质量SPECT图像。设计了一个框架来生成用于多中心SPECT研究的高质量数据。该框架已成功地应用于泛欧计划,以获取健康的对照多巴胺转运蛋白图像数据库。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号