首页> 外文期刊>European journal of nuclear medicine >A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals.
【24h】

A prototype high-resolution animal positron tomograph with avalanche photodiode arrays and LSO crystals.

机译:带有雪崩光电二极管阵列和LSO晶体的高分辨率动物正电子断层扫描仪原型。

获取原文
获取原文并翻译 | 示例
           

摘要

To fully utilize positron emission tomography (PET) as a non-invasive tool for tissue characterization, dedicated instrumentation is being developed which is specially suited for imaging mice and rats. Semiconductor detectors, such as avalanche photodiodes (APDs), may offer an alternative to photomultiplier tubes for the readout of scintillation crystals. Since the scintillation characteristics of lutetium oxyorthosilicate (LSO) are well matched to APDs, the combination of LSO and APDs seems favourable, and the goal of this study was to build a positron tomograph with LSO-APD modules to prove the feasibility of such an approach. A prototype PET scanner based on APD readout of small, individual LSO crystals was developed for tracer studies in mice and rats. The tomograph consists of two sectors (86 mm distance), each comprising three LSO-APD modules, which can be rotated for the acquisition of complete projections. In each module, small LSO crystals (3.7 x 3.7 x 12 mm3) are individually coupled to one channel within matrices containing 2x8 square APDs (2.6 x 2.6 mm2 sensitive area per channel). The list-mode data are reconstructed with a penalized weighted least squares algorithm which includes the spatially dependent line spread function of the tomograph. Basic performance parameters were measured with phantoms and first experiments with rats and mice were conducted to introduce this methodology for biomedical imaging. The reconstructed field of view covers 68 mm, which is 80% of the total detector diameter. Image resolution was shown to be 2.4 mm within the whole reconstructed field of view. Using a lower energy threshold of 450 keV, the system sensitivity was 350 Hz/MBq for a line source in air in the centre of the field of view. In a water-filled cylinder of 4.6 cm diameter, the scatter fraction at the centre of the field of view was 16% (450 keV threshold). The count rate was linear up to 700 coincidence counts per second. In vivo studies of anaesthetized rats and mice showed the feasibility of in vivo imaging using this PET scanner. The first LSO-APD prototype tomograph has been successfully introduced for in vivo animal imaging. APD arrays in combination with LSO crystals offer new design possibilities for positron tomographs with finely granulated detector channels.
机译:为了充分利用正电子发射断层扫描(PET)作为组织表征的非侵入性工具,正在开发专用的仪器,该仪器特别适合对小鼠和大鼠进行成像。诸如雪崩光电二极管(APD)之类的半导体检测器可为光电倍增管提供替代方案,用于读出闪烁晶体。由于正硅酸lut(LSO)的闪烁特性与APD很好地匹配,因此LSO和APD的组合似乎是有利的,并且本研究的目标是构建带有LSO-APD模块的正电子断层扫描仪,以证明这种方法的可行性。 。开发了一种基于APD读数的小型LSO晶体的原型PET扫描仪,用于在小鼠和大鼠中进行示踪研究。断层扫描仪由两个扇区(86毫米距离)组成,每个扇区包括三个LSO-APD模块,可以旋转这些模块以获取完整的投影。在每个模块中,小型LSO晶体(3.7 x 3.7 x 12 mm3)分别耦合到包含2x8平方APD(每个通道2.6 x 2.6 mm2敏感面积)的矩阵内的一个通道。使用惩罚加权最小二乘算法重建列表模式数据,该算法包括断层扫描仪的空间相关线扩展函数。用体模测量基本性能参数,并进行了大鼠和小鼠的首次实验,以介绍该方法用于生物医学成像。重建的视场覆盖68毫米,占探测器总直径的80%。在整个重建视场中,图像分辨率显示为2.4毫米。使用450 keV的较低能量阈值,对于视野中心的空气中的线源,系统灵敏度为350 Hz / MBq。在直径为4.6 cm的充满水的圆柱体中,视野中心的散射分数为16%(阈值450 keV)。计数率是线性的,最高可达每秒700个符合计数。麻醉的大鼠和小鼠的体内研究表明,使用这种PET扫描仪进行体内成像的可行性。第一台LSO-APD原型断层扫描仪已成功引入体内动物成像。 APD阵列与LSO晶体相结合,为具有精细颗粒检测器通道的正电子断层扫描仪提供了新的设计可能性。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号