...
首页> 外文期刊>European heart journal. Acute cardiovascular care >Effectiveness, safety and feasibility of an evidence-based insulin infusion protocol targeting moderate glycaemic control in intensive cardiac care units
【24h】

Effectiveness, safety and feasibility of an evidence-based insulin infusion protocol targeting moderate glycaemic control in intensive cardiac care units

机译:针对重症监护病房中度血糖控制的循证胰岛素输注方案的有效性,安全性和可行性

获取原文
获取原文并翻译 | 示例
           

摘要

Objectives: To assess the effectiveness, safety and feasibility of the revised, simplified nurse-managed version of our insulin infusion protocol, adapted to the new recommended glycaemic target of 140 to 180 mg/dL (Desio Diabetes Diagram i.v. 140-180).Methods: All clinical responses to the Desio Diabetes Diagram i.v. 140-180 in use for 3 years were recorded in patients with diabetes or hyperglycaemia admitted to our intensive cardiac care unit. To assess the feasibility, we asked nurses to complete an ad hoc questionnaire anonymously when the new insulin infusion protocol had been in use for 2 years. Results: From December 2010 to December 2013, 276 patients (173 men, median age 75 years) were treated according to the Desio Diabetes Diagram i.v. 140-180. The median time to reach glycaemic target was 4 h (QI-Q3 2-8) in 128 patients with blood glucose > 180 mg/dL and 2 h (QI-Q3 1-4) in 82 patients with blood glucose <140 mg/dL Once the target had been reached, insulin infusion was maintained for a median of 38 h (QI-Q3 24-48) with blood glucose between 140 and 180 mg/dL for 58.3% of the infusion time. Over a total of I 1,863 h of infusion, seven blood glucose <70 mg/dL occurred. The Desio Diabetes Diagram i.v. 140-180 protocol was considered easy to use by 93% of nurses. Conclusions: The Desio Diabetes Diagram i.v. 140-180 protocol, fully managed by nurses, with insulin and glucose intravenous infusion proved effective, safe and feasible in maintaining blood glucose between 140 and 180 mg/dL in patients with diabetes or hyperglycaemia admitted to the intensive cardiac care unit for acute cardiac events.
机译:目的:评估胰岛素输注方案经修订,简化的护士管理版本的有效性,安全性和可行性,以适应新推荐的140至180 mg / dL的血糖目标(Desio Diabetes Diagram iv 140-180)。 :对Desio糖尿病图的所有临床反应iv进入我们的重症监护病房的糖尿病或高血糖患者记录了140-180使用3年的情况。为了评估可行性,我们要求护士在新胰岛素输注方案使用2年后匿名填写临时问卷。结果:从2010年12月至2013年12月,根据Desio Diabetes Diagram i.v.治疗276例患者(173名男性,中位年龄75岁)。 140-180。血糖> 180 mg / dL的128位患者达到血糖目标的中位时间为4 h(QI-Q3 2-8),血糖<140 mg / d的82位患者达到血糖目标的中位时间为2 h(QI-Q3 1-4) dL一旦达到目标,胰岛素输注将保持中位38小时(QI-Q3 24-48),血糖在140至180 mg / dL之间,持续58.3%的输注时间。在总共1,863小时的输注过程中,发生了七个血糖<70 mg / dL的血糖。 Desio糖尿病图140-180协议被93%的护士认为易于使用。结论:Desio糖尿病图i.v.经护士充分管理的140-180方案,经胰岛素和葡萄糖静脉输注被证明有效,安全且可行,可将糖尿病或高血糖患者的葡萄糖或血糖维持在140到180 mg / dL之间,以接受急性心脏事件。

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号