A novel control method for active power filters in conjunction with a cascaded passive filter circuit is presented and analysed in this paper in order to comply with EMC regulations. The principles of analysis, design, operation and control of the new circuit equipped with IGBTs are presented. This enables the compensation of rapidly changing harmonics and reactive power. The new configuration improves the rating of the active power filter reducing power losses in the switches compared to existing and newly developed active filters. Furthermore, the paper also presents a mathematical modelling of the proposed system equations. The frequency response of the proposed system is also discussed. The proposed circuit has been checked using a dedicated software simulation program, which was specifically developed for this purpose. An experimental set-up has been designed and implemented in order to apply the new method using IGBTs and other passive devices.
机译:本文提出并结合级联的无源滤波器电路对有源功率滤波器进行了新颖的控制,以符合EMC法规。提出了配备IGBT的新电路的分析,设计,操作和控制原理。这样可以补偿快速变化的谐波和无功功率。与现有的和新开发的有源滤波器相比,新配置提高了有源功率滤波器的额定值,从而减少了开关中的功率损耗。此外,本文还提出了所提出的系统方程的数学模型。还讨论了所提出系统的频率响应。建议的电路已使用专用的软件仿真程序进行了检查,该程序专门为此目的开发。为了使用IGBT和其他无源器件应用新方法,已经设计并实施了实验装置。