首页> 外文期刊>Environmental Sciences >Specific Dual Beam Fluorometry Analysis of Benzo[a]pyrene and Benzo[k]fluoranthene in Diesel Exhaust Particulate Samples
【24h】

Specific Dual Beam Fluorometry Analysis of Benzo[a]pyrene and Benzo[k]fluoranthene in Diesel Exhaust Particulate Samples

机译:柴油尾气颗粒样品中苯并[a] py和苯并[k]荧蒽的特定双光束荧光分析

获取原文
获取原文并翻译 | 示例
           

摘要

We developed a specific analysis method for benzo[a]pyrene (B[a]P) and benzo[k]fluoranthene (B[k]F) using dual beam fluorometry.B[a]P and B[k]F exhibited two specific fluorescence intensities (up to 10-fold) compared with 22 other poly cyclic aromatic hydrocarbons (PAHs) at 370 nm excitation and 429 nm emission wavelengths,and similarly at 395 nm excitation and 429 nm emission wavelengths.The concentrations of these compounds in diesel exhaust particles were calculated from two calibration curves determined using a mixture of 24 PAH standards.The precision of this detection method was compared with that of conventional high-performance liquid chromatography/fluorescene detector (HPLC/FLD),and our method gave accurate values within the analytical standard deviations.The monitoring method developed in this study will enable more rapid and easier detection.
机译:我们开发了一种使用双束荧光法分析苯并[a] py(B [a] P)和苯并[k]荧蒽(B [k] F)的特定分析方法。B[a] P和B [k] F表现出两种与其他22种其他多环芳烃(PAHs)在370 nm激发和429 nm发射波长下以及在395 nm激发和429 nm发射波长下的特定荧光强度(高达10倍)相比,这些化合物在柴油中的浓度根据混合使用24种PAH标准品测定的两条校准曲线计算出废气颗粒,并将此检测方法的精度与常规高效液相色谱/荧光检测器(HPLC / FLD)的精度进行了比较,我们的方法给出的准确值在分析标准偏差。本研究开发的监测方法将使检测更快,更容易。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号